Page 16
1. Ensure the dryer is shut down
and fully depressurised before
attempting any maintenance work.
(See Page 8, section 4.1)
2. Remove the top cover screws
and remove the cover. (See Figure
D.1)
3. Release the catches located at
the top and bottom of the shroud
to open it (See Figure D.1.1)
4. Remove the screw from the
sensor plug (Figure D.2) and
detach it from the dew point
sensor assembly. (See Figure D.2.1)
Figure D.1
TOP COVER
SCREWS
PLUG SCREW
SHROUD LATCH
DEW POINT PLUG
CONTROLLER
CHASSIS PLATE
Figure D.2
7. SERVICE ‘D’ INSTRUCTIONS - Dew point sensor
(Every 1 year or 6,000 hours)
REPLACING OR RECALIBRATING THE DEW POINT SENSOR - ES MODELS ONLY
Figure D.2.1
Figure D.1.1