© by N&W GLOBAL VENDING S.p.A.
11
03 - 2011 3685 00
START-UP
Every time the machine is connected to the power sup-
ply, the display will show the image
after that, the vending machine software version num-
ber is displayed together with the software review of the
machine board.
It is possible to programme the machine for displaying,
for a few seconds, the number of dispensed items (total
number of strokes)
Krea Rev. X.XX
Machine Board Rev. X.XX
Total number of strokes = XXXXXX
After that, the boiler is checked and the heating cycle is
started
HEATING PHASE
Temperature= XX°C
At the end of the heating cycle, after a few seconds, the
display shows the message with the invitation to select
the drink and the lighting of the machine is activated.
CHOOSE THE
DRINK
p
assWorD
iNpuT
WiTH
closED
Door
In order to safely perform some of the cleaning opera-
tions which require the machine to be in operation, it
is possible to use the selection buttons in sequence
(password).
The password input with closed door allows the per-
formance of the operation associated with the entered
password, which means:
-Wash the mixer
-Wash the infuser unit
-Reset the waste counter
To enter the password with closed door, proceed as fol-
lows:
-Press and hold button number 9 (see Fig. 11) for two
seconds.
-The management software asks for the input of a pass-
word and the keyboard adopts the numerical values
shown in the figure below.
The machine remains in standby for a few seconds for
the input of the password (5 digits) which allows you
to perform the operation associated with the entered
password.
These passwords can be defined in the Engineer Menu.
By default, all the passwords are disabled.
SERVICE SUSPENSION
If, for any reason, the vending machine remains off for a
period longer than the expiry dates of the products, it is
necessary to:
-Completely empty the containers and wash them care-
fully with the sterilising products used for the mixers.
-Completely empty the grinder-doser by dispensing cof-
fee until the notification that the machine is empty.
-Completely empty the boiler and the air-break by loos-
ening the screw on the corresponding pipe.