© by N&W GLOBAL VENDING S.p.A.
20
03 - 2011 3685 00
D
osE
sETTiNg
Four different doses are managed on the doser: one low
dose (e.g., for a single coffee), two intermediate doses
and one high dose (e.g., for a double coffee).
The coffee unit can accept up to 12 g of coffee.
-If the totally volumetric high dose is chosen (100% time
- two releases), it will be necessary not to adjust the
doser volume to more than 6 grams.
In this case, the dose for the single coffee will be 6 g
(volume) plus the grams ground in the programmed
time (volume grinding other than 100%).
-If the totally volumetric low dose is chosen, it will be
necessary to adjust the volume to the desired dose
with the addition of 0 % time-ground grams.
In this case the intermediate doses and the highest
dose will be composed of the volume-dosed grams
with the additions of the grams ground in the pro-
grammed time (volume grinding other than 0%).
-
Warning!
If the position of the adjustment lever is
changed, the percentage value of the added dose will
have to be reset.
Important!!!
Test releases can be performed using the appropriate
function of the “Test” menu in the “Engineer” mode (see
relevant paragraph); the released doses should be col-
lected by removing the coffee unit in order to prevent the
leakage of coffee inside the machine.
The layouts provide for a combination between the
selections and the dose which, in any case, can be
changed.
It is possible to modify the combination of the doses and
selections determined based on the product used and
the desired beverage quality.
The default setting of the machine is indicated in the
doses-selections table supplied with the machine.
c
offEE
DosE
combiNaTioN
Even though this combination can be changed, the
choice to do so should be made very carefully since it
has a substantial effect on the quality of the dispensed
drink.