Page 74
6-13
Replacing the Ball Slide
1.
Remove the Gun Side Right.
2.
3.
Remove 2off pozi head screws (M3x6), with flat and spring washers.
4.
Compress the spring, remove the spacer from the main frame, and remove the
slide unit by lifting it out, taking care not to loose the spring when removing the
slide unit from the main frame.
5.
Remove 2off pozi head screws (M3x6), with spring washers, to seperate the Ball
Slide from the Slide Weight.
6.
Reassemble in reverse order.
Note: If the cam surface is damaged, replace the cam. (see 6-12 page 70)
Make sure that the recoil unit moves freely before closing the gun body.
Note: After replacing the Motor, be sure to conduct a motor test.
Pozi head screw (M3x6)
Spring
Pozi head screw (M3x6)
Spring washer
Ball slide
Slide weight
Spacer
Main frame
Slide unit