Page 67
6-6
Replacing the Camera Assy
1.
Remove 4off security screws (M5x15), lift the Camera Cover only sufficient to
disconnect the connectors.
2.
Remove 2off Whizz nuts (M4), Earth terminal and toothed washer. Remove the
Camera Assy.
3.
Remove 2off pozi head screws (M2x30) to remove the CCD Camera.
4,
Reassemble in reverse order.
Note: Ensure that the Gun is reinitialized after changing.
. Failure to reinitialize the Gun will prevent
the game operating correctly
When reinstalling the CCD Camera ensure that the Camera Filter is fitted the
correct way round. (The front face has countersunk holes)
Security screw (M5 x 15)
Connectors
Earth wire
Earth terminal
(on one side only)
Whizz nuts (M4)
Camera cover
Camera unit
Toothed lock washer
Pozi head screws
(with flat and spring washers) (M2 x 30)
Connector
Camera filter (note the direction)
CCD camera
(connector on the bottom side)