NAL Research Corporation (TN2012-02-V1.0)
41
A.8.64 S0=n – Auto-Answer
Auto-answer. This causes the A3LA-RS to auto-answer the incoming data (or voice call for
A3LA-R/RM/RGS).
0
Disable auto-answer.
n>0
Enable auto-answer after n rings
A.8.65 Xn – Extended Result Codes
Select the response set to be used by the A3LA-RS when informing the DTE of the results of a
command or data (or voice call for A3LA-R/RM/RGS).
0
OK, CONNECT, RING, NO CARRIER, NO ANSWER and ERROR
CONNECT response is used to inform of a data call connection; OK response is used
to inform of a voice call connection (only for A3LA-R/RM/RGS).
1
As X0 plus CONNECT x, where x is the DTE speed
CONNECT x response is used for data calls only.
2
As X1 plus NO DIALTONE
3
As X2 plus BUSY
4
As X3 plus CARRIER x, PROTOCOL: and COMPRESSION:, where x is the line speed
(default)
CARRIER x, PROTOCOL:, and COMPRESSION: responses are used for data calls
only.
Note that the Wn command limits which connection related responses will be reported.
A.8.66 +CLVL – Volume Level Control (Not Applicable to A3LA-RS)
Exec Command:
+CLVL=<level>
This command is used to select the ‘volume’ of the audio on the audio path. <level> is an
integer type value with the smallest value representing the lowest sound level.
Read Command:
+CLVL?
Query the current volume level settings. The response is in the form:
+CLVL: <level>
0
Equivalent to level 0 displayed on a handset’s volume indicator
1
Equivalent to level 1 displayed on a handset’s volume indicator
2
Equivalent to level 2 displayed on a handset’s volume indicator
3
Equivalent to level 3 displayed on a handset’s volume indicator
4
Equivalent to level 4 displayed on a handset’s volume indicator
5
Equivalent to level 5 displayed on a handset’s volume indicator
6
Equivalent to level 6 displayed on a handset’s volume indicator
7
Equivalent to level 7 displayed on a handset’s volume indicator
Test Command:
+CLVL=?
List the supported volume level settings. The response is in the form:
+CLVL: (supported <level>s)
A.8.67 +CMUT – Mute Control (Not Applicable to A3LA-RS)