Page 7
www.NabcoEntrances.com
05-11-10
Acuvision Instruction Manual
Note !
Because sensor “looks”
backward through the threshold
area, it must not be obstructed
by the mounting surface.
Therefore, when using sensor
on swing, fold, or sliding doors,
install no higher than 1.5”
above bottom of header as
shown at right.
Color of wire
Function
Notes
Brown
12VDC
24VAC
Use “Class 2” Power Supply
Red
GND
Black
(N.O.)
OUTPUT #1 --- Activation Signal Output
30VAC/50VDC 0.1A Max.
(Resistance load)
[Semiconductor Relay]
Green
(COM)
Gray
(INPUT)
INPUT #1 --- Fully Closed Signal Input
If there is a possibility of swing /folding doors open-
ing slightly from the fully closed position due to wind
or stack pressure, this input signal may be required
in order for the sensor to recognize when the door is
in the fully closed position. A mechanical or magnet-
ic door closed switch is necessary for this function.
This signal can be output automatically from
Microprocessor U series. (No signal required on
Sliding doors.)
A dry switch contact is required.
For swing doors use:
1 x P/N 14-11313
For folding doors use:
1 x P/N 14-11343-20
1 x P/N 14-11313-20
Yellow
(INPUT)
White
(N.O.)
OUTPUT #2 --- Safety Signal Output
<
Swing/folding side of the Swing/Folding Doors>
Safety Signal Output:
Connected
to Locked out
safety input of Control box.
<Sliding Door>
Not used
30VAC/50VDC 0.1A Max.
(Resistance load)
[Semiconductor Relay]
Blue
(COM)
D.2
Wiring
D.2.1) General Wiring Information
Sensor should be installed
no higher than 1.5” from
the bottom edge of header
DN0183