![Nabco Gyro Tech Acuvision Instruction Manual Download Page 8](http://html1.mh-extra.com/html/nabco/gyro-tech-acuvision/gyro-tech-acuvision_instruction-manual_3084250008.webp)
Page 8
www.NabcoEntrances.com
05-11-10
Acuvision Instruction Manual
D.2.2) Wiring - Sliding Door with U Series Control
Cut the (3) pin connector off of the existing Acusensor extension harness (PN # 22-9267).
Wire nut the two harnesses together as shown below. Insert the new Acuvision cable
(PN # 22-11023) into the hole in the header cover so the connector is on the exterior of the cover.
Mount the Acuvision Sensor. Note: Acuvision dipswitch Settings: (9 ON & 10 OFF)
DN0183
D.2.3) Wiring - Non-swing side of swing door or non-fold side of fold door with U Series Control
Insert new Acuvision cable (PN # 22-11023) into drilled hole in header. Cut Quick Disconnect
connector off main microprocessor harness as shown. Wire nut Acuvision harness to main harness
as shown below. Mount the Acuvision Sensor.
Note: Acuvision dipswitch Settings: (9 ON & 10 OFF)
DN0183
RED
YELLOW
GRAY
Cut
# 22-9267-00
ACUSENSOR
EXTENSION HARNESS
NOT USED
YELLOW
NOT USED
NOT USED
NOT USED
12/24 VOLTS AC/DC
ACUVISION HARNESS
RED
GRAY
BROWN
RED
GREY
YELLOW
GREEN
BLACK
BLUE
WHITE
12/24 VOLTS AC/DC
INPUT
INPUT COM
OUTPUT#1 N.O.
OUTPUT#1 COM
OUTPUT#2 N.O.
OUTPUT#2 COM
HOLE ON
THE
HEADER
COVER
RED
BLACK
BROWN
Cut
RED
BLACK
OUTPUT#1 N.O.
OUTPUT#1 COM
OUTPUT#2 COM
OUTPUT#2 N.O.
GREEN
BLACK
WHITE
BLUE
INPUT COM
INPUT
YELLOW
GREY
RED
BROWN
BROWN
HOLE ON
THE
HEADER
COVER
QUICK DISCONNECT ON
MICROPROCESSOR
MAIN HARNESS
ACUVISION HARNESS
NOT USED
NOT USED
NOT USED
NOT USED
12/24 VOLTS AC/DC
12/24 VOLTS AC/DC