D.2.4) Wiring - Non-swing side of swing door with Magnum Control
Insert new Acuvision cable (PN # 22-11023) into drilled hole in header. Connect Acuvision
harness to Magnum terminal block as shown below. Mount the Acuvision Sensor.
Note: Acuvision dipswitch Settings: (9 ON & 10 OFF)
DN0183
DN0183
BLACK
TERMINAL # 6
MAGNUM BOARD
TERMINAL BLOCK
CONNECTIONS
RED
ORANGE
BROWN
BROWN
RED
GREY
YELLOW
BLUE
WHITE
BLACK
GREEN
INPUT
INPUT COM
OUTPUT#2 N.O.
OUTPUT#2 COM
OUTPUT#1 COM
OUTPUT#1 N.O.
HOLE ON
THE
HEADER
COVER
ACUVISION HARNESS
TERMINAL # 1
TERMINAL # 2
NOT USED
TERMINAL # 5
NOT USED
NOT USED
NOT USED
12/24 VOLTS AC/DC
12/24 VOLTS AC/DC
24 VAC
24 VAC
HOLE
ON THE
HEADER
COVER
TRANSFORMER
P/N 14-2101
TO EXTERNAL
LOCKOUT MODULE
TO RED (COMMON)
OUTPUT#1 N.O.
OUTPUT#1 COM
OUTPUT#2 COM
OUTPUT#2 N.O.
INPUT COM
INPUT
BLACK
GREEN
BLUE
WHITE
YELLOW
GREY
RED
BROWN
RED WIRE ABOVE IS FOUND
ON FOUR WIRE MAT HARNESS
ON ANALOG CONTROL
ACUVISION HARNESS
DOOR CLOSED INPUT
SEE NOTE ON PG. 18
12/24 VOLTS AC/DC
12/24 VOLTS AC/DC
NOT USED