NDC- 8 OUTDOOR PANEL
20
A - Program button
B - Panel ID Tuning
C - Midrophone Volume Control
D- Speaker Volume Control
E- Indicator LED.
FIGURE-3.2
ON
ON
4 3 2 1
A
B
C
D
MIC
SPK
E
LED 1
LED 2
ON
ON
MIC
SPK
Camera Angle Tuning
Camera Lens
Camera Lighting LEDs
Speaker Volume Control
Microphone Volume Control
Speaker
System Cable Connection
Calling Button
Name Plate
Microphone
FIGURE-3.1
Power Consumption
Operating Time
Material Content/Colour
Dimensions
Operating Temperature
Camera
Camera Angle
Protection Class
Functions
14W (max.), 4W (min.), 24V
±
1V (
from central unit
)
Call : 30sec. Videocall : 60sec.
Aluminum / Metallik Grey
8NDC 244
(244x115x25 mm.)
8NDC 320
(320x115x25 mm.)
8NDC 396
(396x115x25 mm.)
-20°C - + 40°C
1/4 inch CCD
86° stable, 10° adjustable camera angel
IP44
‹ntercom function , videophone function, LED illimunator for camera,
adjustable speaker and microphone audio levels, suportt max 52 flat
TECHNICAL CHARACTERISTICS
PANEL FUNCTIONS:
Camera view ange :
Used for adjusting camera view angle as shown in figure 3.1
Program button :
Used for assigning a bell button as an externail doorkeper or terminating an external
doorkeeper function as shown in figure 3.2-A
Panel ID setting :
DIP Switch that is indicated in FIGURE-3.2.B is used for ID settings. Please refer TABLE-3.1 for ID range.
Indicator LED :
Status Indicator LEDs show currnet stuation of Programme button and Central Unit’s function as shown in
Figure-3.2.E
Microphone Volume Control :
Potantiometer that is indicated in FIGURE – 3.2.C used for adjusting the outgoing volume
from panel to apartments.
Speaker Volume Control :
Potantiometer that is indicated in FIGURE – 3.2.D used for djusting the incoming volume from
apartments to panel. It can be made a specialist with using a screw driver.
Be careful to make sure all ID depended devices are set by unique IDs before the system is
energised. In order to multiple panel operations, be careful that all panelÅfs are set by IDs different
from “0” as shown in table 3.1.
Explanations:
** If LD1 flashes then it means panel ID is not assigned yet as shown in figure 3.2-E.
Panel must be re scanned by CENTRAL UNIT with using
“Switch to SETUP MODE from NORMAL MODE by deleting
all records”
function.
** If LD2 flashes then it means Panel is scanning in SETUP MODE, otherwise if it is continously turned off then it means
CENTRAL UNIT is in NORMAL MODE.