Operation
operation and installation manual
zappi
9
Display Icons Key
House Consumption – Not Importing
Charge Mode = FAST
House Consumption – Importing
Charge Mode = ECO
Solar Generation Power
Charge Mode = ECO+
Charge Mode = STOP
Wind Generation Power
zappi
Device – Normal
On the three phase
zappi
the number in
the icon indicates whether the EV is
charging with a single phase or all three
phases.
Grid Power – Import / Export
zappi
Device – Too Warm (output
limited)
Power Flow Direction – Small Amount
Import Power Limiting Active
Power Flow Direction – Medium Amount
Economy Tariff Electricity Available
Power Flow Direction – Large Amount
Current Charging Power
Waiting for Surplus Power
Energy sent to EV for this charge
DSR Mode (demand-side response)
2
Warning – refer to text on screen
Lock icon –
zappi
or cable locked
(untethered versions only)
RGB Indicator
The lighting flash indicator on the front of the
zappi
indicates the status of the charge. The default colours are:
Pink:
Connected
Green:
Charging 100% Green
White:
Charging from Grid only
Yellow:
Charging mix of grid/green energy
Blue:
Charge complete
Red:
Error
These colours can be adjusted on Display & Sound menu (firmware version 2.163 onwards)
The colour effect (pulsing of the LED brightness) varies according to the charging power
2
DSR – Demand Side Response – A smart feature for future use by electricity suppliers and distribution companies
to help manage load on the electricity system at times of high demand. This feature can only be enabled by the owner
of the
zappi