Charging Modes
STOP
All charging is stopped.
zappi
will not charge the EV, Boosts (manual, smart and scheduled) are also disabled.
ECO
Charge power is continuously adjusted in response to changes in generation or power consumption
elsewhere in the home.
Charging will continue until the vehicle is fully charged, even if power is drawn from the grid.
ECO+
Charge power is continuously adjusted in response to changes in generation or power consumption
elsewhere in the home.
Charging will pause if there is too much imported power, continuing only when there is sufficient
surplus power available.
FAST
In this mode, the vehicle will be charged at maximum power.
This is just like an ordinary Mode 3 charging point.
Model Variants
Model No.
Rating
Connector
Colour
ZAPPI
-2H07UW
7kW
Untethered
White
ZAPPI
-2H07TW
7kW
Tethered
White
ZAPPI
-2H07UB
7kW
Untethered
Black
ZAPPI
-2H07TB
7kW
Tethered
Black
ZAPPI
-2H22UW
24kW (3-Phase)
Untethered
White
ZAPPI
-2H22TW
24kW (3-Phase)
Tethered
White
ZAPPI
-2H22UB
24kW (3-Phase)
Untethered
Black
ZAPPI
-2H22TB
24kW (3-Phase)
Tethered
Black
Designed to permit installations compliant with IET Wiring Regulations BS 7671:2018 Amendment 1:2020 and the