Short press power button adjust the gear,1-5 file circulation regulation, energy incrementally, please
from a file at the beginning of the test, gradually adjusted to their own comfortable stalls. Higher gear,
the higher the intensity of light, to achieve the effect will be better.

从高档位调节回低档位时,灯会自动熄灭,重新调节后亮起绿灯。

The light will turn off when the higher gear adjust to the lower gear, it light green after readjustment.

长按出光键约

2

秒,切换滑动出光和手动出光;蓝色灯亮时为滑动出光模式,贴近皮肤后自动

出光;蓝色灯灭时为手动出光,此时贴近皮肤绿色灯闪烁时短按出光键即可出光。

Long press out of light button for 2 seconds can switch sliding out of the light and hand out the light;
the light blue turn on is sliding out of the light pattern, it will automatic out of light after near the skin;
the light blue turn off is hand out the light, the green light flicker when near the skin, short press the
button can out of light.

P13

使用时的注意事项

Precautions when using it

1.

首次脱毛需要刮毛

The first time using hair removal needs to shave hair.

2.

产品上电时会记忆当前的感应状态,通电前请确保灯头位置正前方

10

厘米内无任何遮挡物,以

免影响正常使用。

When the product is powered, it will remember the current sensing state. Before powering on, make
sure that the lamp holder is in front of 10 cm without any obstruction, so as not to affect the normal
use.

3.

如脱毛部位皮肤有伤口感染,请不要使用本产品。

If the skin is wound infection, please do not use this product.

4.

不要在同一位置连续闪光

2

次以上,以免烫伤皮肤。

Do not flash in the same position more than 2 times, so as not to burn the skin.

5.

在首次使用时,请不要直接使用最高档,先从低档往上测试。

In the first use, please do not directly use the most high-end, first from the low up to test.

6.

使用脱毛仪的时候,滤光片会升温,为防止烫伤,只需要仪器轻贴皮肤即可,请勿大力度往下
按。

When using the hair removal device, the filter will heat up, in order to prevent burns, just need to
light the skin can be, please do not press down.

7.

注意脱毛后护理,脱毛后

48

小时内不要曝晒,外出请涂抹防晒霜(具体请参考说明书第

14

日晒建议和护理)

Note that after hair removal care, do not touch within 48 hours after hair removal, go out to apply
sunscreen (please refer to the instructions on page 14 sun recommendations and care)

8.

脱毛后可以擦无香味的保湿霜,如芦荟胶,以免皮肤干燥,出现轻微红肿和痒是属于正常现象。

After hair removal can be wiped with no fragrance moisturizing cream, such as aloe vera gel, so as to
avoid dry skin, a slight redness and itch is a normal phenomenon.

9.

脱毛完成后,请用酒精和棉签擦拭灯头出光窗口,以免影响效果。不使用时请放在干燥的环境
中保存。

After the hair removal is completed, please use alcohol and cotton swab to wipe the lamp window, so

Summary of Contents for HR-541

Page 1: ...ter P5 Specification DC12V Rated Input Power DC12V 10 C 60 C Storage temperature 10 C 60 C 36W Maximum Input 36W 5 80 Storage relative humidity 5 80 5 C 50 C Working temperature 5 C 50 C 3 0cm 1 0cm 3...

Page 2: ...er washbasin or pool etc Keep the product and the adapter dry P6 This product is not suitable for use in the following areas physical decline sensory or mental disorder lack of relevant experience and...

Page 3: ...light and light boxes Only when the optical port in contact with the skin to flash In order to avoid the product from the environment moisture dust food liquid direct exposure to the sun etc should be...

Page 4: ...ive skin cancer or any other local cancer 4 In areas where moles freckles birthmarks large veins and pigmentes are deeper this may cause burns or discoloration which may be more difficult to distingui...

Page 5: ...elaic acid 17 A Roaccutane If in the past six months has been taken oral isotretinoin retinoic acid goods Roaccutane This treatment can make the skin more easily damaged traumatic and allergic 18 When...

Page 6: ...skin Keep the skin clean and free from hair completely dry without oily substances such as cosmetics deodorants lotion perfume tanning and sunscreen etc 3 Check whether the light emitting window is c...

Page 7: ...arate light intensity If any discomfort occurs anywhere you need to reduce the intensity of light 1 5 X In the following table the recommended light intensity is 1 5 X means inappropriate Skin color w...

Page 8: ...ct is powered it will remember the current sensing state Before powering on make sure that the lamp holder is in front of 10 cm without any obstruction so as not to affect the normal use 3 If the skin...

Page 9: ...to their own hair growth rate to determine the hair removal time The first 6 times the shortest interval not shorter than 3 days the longest not more than 15 days P14 Insolation recommendations and ca...

Page 10: ...to cool to room temperature and then turn off the main unit Note The UV filter will heat up during use Make sure it is cooled and then cleaned 2 Use medical alcohol to clean the window Note The contam...

Page 11: ...ing this product During the hair removal the skin feels more sensitive than usual The intensity of the used light is too high Check whether the correct light intensity is selected If necessary select...

Page 12: ...4 5 1 2 1 3 2 3 In order to achieve a better hair removal effect the use of this product is the light spot must overlap 4 5 level recommended operation 1 2 times 1 3 level recommended operation 2 3 ti...

Page 13: ...work P19 Warranty and service warranty period Our company to the date of purchase of the product shall prevail where the quality of the problems arising from the manufacturing cause by our company is...

Page 14: ...mpany P20 If you belong to the following points the company will be irresponsible not within the scope of the warranty a Faults and damage caused by fire earthquake third party behavior intentional or...

Page 15: ...thin one year life long maintenance warranty equipment during the warranty period in the normal use and maintenance of the circumstances product materials and process problems failure the test is true...

Reviews: