210208_A
mychefcooking.com
61
PRODUCT MANUAL SERIE L EVOLUTION - DT.MP.LE.2103.2
Error
Internal definition
Notes
0
NO ERROR
No error.
1
ERROR GENERAL PURPOSE
INPUT
General error input. Not used.
2
ERROR OVERTEMPERATURE
General over temperature input. Not used.
3
ERROR OVERTEMPERATURE
PCB
Over temperature PCB. Check that the cooling
fans of the electronics are working properly, that
there is sufficient space between the rear and the
wall, and that the ambient temperature is not too
high.
4.1
ERROR COMMUNICATION
Communication between boards is not
responding. Check the cable connecting the
power board and control board.
4.3
ERROR COMMUNICATION
Communication between relay board and inverter
is not responding. Check the cable connecting
both components. Check if the inverter
communication LED blinks.
5
ERROR EEPROM
Communication processor and EEPROM does not
work. Check the control board.
6
ERROR MOTOR
Motor
error.
Check
motor
wiring.
Overtemperature on the motor. Motor failure.
7
ALARM WATER
No water detected. Ensure that the water supply
is connected correctly.
8
ERROR WASHING
No detergent detected. Not used.
9
ERROR PROBE1 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check the external
probe and connector.
10
ERROR PROBE1 TEMP SENSOR
SHORTED
External probe short-circuited. Check the external
probe and connector.
11
ERROR PROBE2 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check the external
probe and connector.
12
ERROR PROBE2 TEMP SENSOR
SHORTED
External probe short-circuited. Check the external
probe and connector.
13
ERROR PROBE3 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check the external
probe and connector.
14
ERROR PROBE3 TEMP SENSOR
SHORTED
External probe short-circuited. Check the external
probe and connector.
15
ERROR PROBE4 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
16
ERROR PROBE4 TEMP SENSOR
SHORTED
Reserved. Not used.