210208_A
mychefcooking.com
11
PRODUCT MANUAL SERIE L EVOLUTION - DT.MP.LE.2103.2
Before starting the electrical installation, check that the electrical requirements of the oven
and the power supply are the same.
Check, once the connection has been made, that no cable is loose, and they are all firmly
fastened. Also secure the cable gland.
Never connect a phase to neutral or ground. Check that the installation
voltages correspond to those of the equipment.
The following subchapters show the three types of possible connections for Mychef ovens.
4.1.1.
Three phase connection 400V 3L+N
Color
Cable
Connector
■
Brown
L1
1
■
Black
L2
2
■
Grey
L3
3
■
Blue
Neutral
4
■
Green-yellow
Ground
Ground
Table 3. Three phase cable 400V 3L+N
4.1.2.
Three phase 230V 3L
Color
Cable
Connector
■
Brown
L1
4
■
Black
L2
1,2
■
Grey
L3
3
■
Green-yellow
Ground
Ground
Table 4. Three phase cable 230V 3L