1.  Your thermostatic concentric mixer valve is set up 

in the factory so that a shower hose can be fitted. 

This means that when the valve is fitted with the hot 

water coming in from the left hand side, indicated 

by the red spot, the water outlet is on the bottom of 

the valve and has a ½” BSP threaded male outlet 

(Fig 1).

2.  The supply pipework can be plumbed from above 

or below but must finish at the suitable connections 

which should be at 155mm centers. Connect the 

15mm pipework using standard compression nut 

and olives supplied with the mixer valve (Fig 2).

NOTE: Make sure the mixer valve is kept in a clean 

place to prevent rubbish etc, getting into the openings 

while fitting the pipework. 

3.  Complete the fitting of the pipework and the tiling 

leaving the pipework as shown.Leave 155mm  

(+ or - 5mm) between centers and about 30mm  

out from the finished surface (Fig 3).

4.  Remove the back plate from the mixer valve by 

removing the retaining grub screws. Put the plate 

in the centre between the feed pipes and mark the 

screw positions, check this fits by holding the valve 

in position. Drill plug and screw the back plate to 

the wall (Fig 4). 

5.  Fit the two flat valve nut covers to the nuts on the 

mixer valve and position the mixer valve onto the 

two water feed pipes and onto the wall bracket. 

To prevent moisture entering the wall put some 

silicone on the underside of the mixer valve nut 

covers.Carefully tighten up  the compression nuts to 

hold the mixer valve in place (Fig 5).

6.  Make sure the mixer valve outlet is pointing in the 

correct direction (with the hot feed on the left side 

marked with a red indicator). Replace the locking 

grub screws to hold the mixer valve onto the wall 

plate.

CAUTION

Check there are no hidden cables or pipes before drilling holes for wall plugs.  

Exercise great care when using power tools near water.  

The use of a residual current device (RCD) is recommended.

!

!

!

!

155mm approx

5

4

3

1

2

Hot Water

 

1/2” Male

Summary of Contents for Atmos Traditional

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Traditional Thermostatic Concentric Mixer Valve with Riser Rail...

Page 2: ...uresystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTA...

Page 3: ...overs 2 FilterWashers 2 HoseRetainingRing 1 10mmAllenKey 1 PressureBalanceKit 1 ScrewPack 2screws 2plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fitting...

Page 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 5: ...ar Thisshouldbeconfirmedbytheinstallation engineerorcompetentperson beforeinstallation WATER TEMPERATURE REQUIREMENTS Maximumhotwatertemperature 80 C Recommendedmaximum 65 C Minimumhotwatertemperature...

Page 6: ...intdown ifthemixervalveisforan overheadtheoutletshouldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto...

Page 7: ...eworkasshown Leave155mm or 5mm betweencentersandabout30mm outfromthefinishedsurface Fig3 4 Removethebackplatefromthemixervalveby removingtheretaininggrubscrews Puttheplate inthecentrebetweenthefeedpip...

Page 8: ...wpositions checkthisfits byholdingthemixervalveinposition Drillplugand screwthebackplatetothewall Fig2 4 Positionthemixervalveontothetwowaterfeed pipesandontothewallbracket Tightenupthe compressionnut...

Page 9: ...riserrail ensuringconeholeisthecorrectwayaroundto holdthehandset Fig3 5 Slideriserrailthroughtopbracketpushing higherthannecessary Screwwallbracketto bottomwallbracketplate Slideriserrailtube throughb...

Page 10: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 11: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 12: ...toyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranypr...

Page 13: ...gineersvisit Theengineerwillnot beabletorepairorreplaceoradviseonpartsor productsnotsuppliedbyMX 4 Intheeventofaservicecallabortedbyyouor whereacallhasbeenbookedunderourguarantee butfailureisnotrelate...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...sales mx group com www mx group com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either thr...

Reviews: