background image

2. TOOLS REQUIRED (NOT SUPPLIED)

1. INTRODUCTION 

This booklet contains all the necessary fitting and 

operating instructions for your MX Thermostatic bar 

mixer shower.

Please read these instructions carefully. Read 

through the whole of this book before beginning your 

installation. 

The shower installation MUST be carried out by a 

suitably competent person in the sequence of this 

instruction book, after reading the instructions.

Care taken during the installation will provide a long 

and trouble free life from your shower. For the best 

performance within the specified running pressure 

range a minimum flow of 5 litres per minute should 

be available on both inlets.

This mixer valve is designed to operate on higher 

pressure systems up to a maximum of 5 bar running 

pressure. The mixer valve must not be subjected to 

water temperatures above 80˚C. This mixer valve is 

also suitable for thermal storage, unvented systems 

and pumped gravity systems.

IMPORTANT: Before installing with a gas 

instantaneous water heater, make sure it is capable 

of delivering hot water at a minimum switch-on flow 

rate of 3 litres per minute. 

At flow rates between 3 and 8 litres per minute, 

the appliance must be capable of raising the water 

temperature to a minimum of 52˚C.

The water temperature at the inlet to the mixer valve 

must remain relatively constant when flow rate 

adjustments are made (refer to the water heater 

operating manual to confirm compatibility with this 

mixer valve).

HB

Silicone

Spanner / Wrench

Tape Measure

Screwdriver

Pencil

Power Drill

Suitable Drill Bits

Silicone Sealant

Spirit Level

Safety Eyewear

NOTE: Additional plumbing tools and fittings may be required.

Summary of Contents for Atmos Traditional

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Traditional Thermostatic Concentric Mixer Valve with Riser Rail...

Page 2: ...uresystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTA...

Page 3: ...overs 2 FilterWashers 2 HoseRetainingRing 1 10mmAllenKey 1 PressureBalanceKit 1 ScrewPack 2screws 2plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fitting...

Page 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 5: ...ar Thisshouldbeconfirmedbytheinstallation engineerorcompetentperson beforeinstallation WATER TEMPERATURE REQUIREMENTS Maximumhotwatertemperature 80 C Recommendedmaximum 65 C Minimumhotwatertemperature...

Page 6: ...intdown ifthemixervalveisforan overheadtheoutletshouldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto...

Page 7: ...eworkasshown Leave155mm or 5mm betweencentersandabout30mm outfromthefinishedsurface Fig3 4 Removethebackplatefromthemixervalveby removingtheretaininggrubscrews Puttheplate inthecentrebetweenthefeedpip...

Page 8: ...wpositions checkthisfits byholdingthemixervalveinposition Drillplugand screwthebackplatetothewall Fig2 4 Positionthemixervalveontothetwowaterfeed pipesandontothewallbracket Tightenupthe compressionnut...

Page 9: ...riserrail ensuringconeholeisthecorrectwayaroundto holdthehandset Fig3 5 Slideriserrailthroughtopbracketpushing higherthannecessary Screwwallbracketto bottomwallbracketplate Slideriserrailtube throughb...

Page 10: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 11: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 12: ...toyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranypr...

Page 13: ...gineersvisit Theengineerwillnot beabletorepairorreplaceoradviseonpartsor productsnotsuppliedbyMX 4 Intheeventofaservicecallabortedbyyouor whereacallhasbeenbookedunderourguarantee butfailureisnotrelate...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...sales mx group com www mx group com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either thr...