AccessZone ® - GC500 Series – GC501-GC504 User Manual
13 Door/Gate Output Type
The GC500 series support 3 different door/gate output types: Pulse, Level or Latched (toggle) to
support different door/gate mechanisms. All types can be combined with a warning buzzer period
before gate activation (warning buzzer can also be switched off).
Select the type suitable for your door or gate.
13.1 Pulse
A 1 second pulse is used to activate the gate and another 1 second pulse is used to close the gate
again after the time out of the “remain gate open time” period.
Door/Gate Output 2
__
___
|¯¯¯|___________________
___
|¯¯¯|___
13.2 Level
A pulse is used to activate the gate. The length of the pulse depends on the “remain open time”
period.
Door/Gate Output 2
__
___
|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
¯¯¯
|___
13.3 Latched (toggle)
The output is kept from one valid access to the next where it changes (toggle).
Door/Gate Output 2
__
___
|¯¯¯¯¯¯
.…..
¯¯¯
¯¯¯
|___