AccessZone ® - GC500 Series – GC501-GC504 User Manual
Total length = 20 digits or optional 22 digits
Examples:
On position 1 - add unique user 0022b4b62918 with PIN
code 1234 enter: "
01,0022b4b62918,1234
"
On position 5 - add unique user 0022b4b62918 without PIN
code enter: "
05,0022b4b62918,0000
"
On position 1 - add unique user 0022b4b62918 without PIN
code and strong enter: "
01,0022b4b62918,0000,1
"
On position 5 - add unique user 0022b4b62918 without PIN
code and weak enter: "
05,0022b4b62918,0000,3
"
Note!
Any exiting user on the selected storage position will be
erased. I.e. it is not necessary to erase an existing user first.
System administrator should maintain a system log of users
and storage positions used. Please see 16 Appendix A –
User Log Template
Caution!
A virtual user is by default (from factory) added on storage position 01 to allow
easy configuration of users without first going through the normal system
configuration mode. The default PIN code is 1234
This corresponds to the command: "01,FFFFFFFFFFFF,1234"
It is highly recommended to overwrite this with a specific user with a unique PIN
code.
The virtual user can be placed on another storage position and other PIN code to
allow access for all users knowing the access PIN code. Please refer to section 11
Virtual Keypad.
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
2010-07-06 US 1.17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web
www.mvc-data.com
Phone +45 25 12 84 02
16/34