AccessZone ® - GC500 Series – GC501-GC504 User Manual
8.5
Change System Configuration Command 2 – Advanced settings
This command can change some additional system settings and thereby customize the system to
your requirements.
Caution!
Caution must be taken when changing these system configuration parameters. Please refer to
section 14.1 Detection Range Command Examples.
Parameters
Values
Description
<power range>,
1 digit
1-3
Maximum transmit power range (TX)
1)
‘1’ ≈ 0,1 m - 2 m
‘2’ ≈ 0,5 m - 10 m
‘3’ ≈ 5 m - 100 m
Default: ‘1’
<TX power level>,
1 digit
1-8
System transmit power (TX) level
1)
1≈0,1 m - 8≈ 10 m
Default: ‘3’
<Detection range>,
2 digits
00-99
Device detection range (RX)
1)
“00”=shortest distance, “99” longest distance
Default: “40”
<Input1 active level >,
1 digit
0 or 1
‘0’=low active (GND), ‘1’=high active (open)
Default: ‘0’
<Input2 active level >,
1 digit
0 or 1
‘0’=low active (GND), ‘1’=high active (open)
Default: ‘0’
<Output1 active level >,
1 digit
0 or 1
‘0’=low active (GND), ‘1’=high active (12V DC)
Default: ‘1’ (Open collector output for
alarm/light)
<Output2 active level >
1 digit
0 or 1
‘0’=low active (GND), ‘1’=high active (12V DC)
Default: ‘1’ (Open collector output for
gate/door)
Note!
Input 3 and input 4 are by default low active ‘0’ (GND) and cannot be changed.
1)
The figure show the relation between TX and RX. A mobile phone must be within the RX (green)
zone and TX should ideally be on RX or a little longer
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
2010-07-06 US 1.17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web
www.mvc-data.com
Phone +45 25 12 84 02
20/34
TX
RX
TX
RX
Mobile phone is
granted access
Mobile phone is
NOT detected
A mobile phone between
TX and RX is detected but
no access