2.5 Sharing post feature
Hydro-Park 1127 & 1123
USER MANUAL
05
MUTRADE INDUSTRIAL CORP.
Unit
A
2551
2651
2751
2851
2100
2200
2300
2400
Total width
required
Clear platform
width
Unit
A
+
B
4937
5137
5337
5537
2100
2200
2300
2400
Total width
required
Clear platform
width
Unit
A
+
B
+
B
7323
7523
7723
7923
2100
2200
2300
2400
Total width
required
Clear platform
width
Notes:
Clear platform width of 2100 mm for car widths of 1850 mm. Layout dimensions should fit for specific order details
if the platform width is customized.
According to ISO 3864 the floor has to be marked with 100 mm wide yellow-black at a distance of 500 mm from
the platform edge by the purchaser (to be performed according to local regulations.)
The lowering speed of an empty platform is considerably lower than a loaded one.
It is not possible to have channels or undercuts and/or concrete haunches along the floor-to-wall joints. If channels
or undercuts are necessary, the system width needs to be reduced or the installation width needs to be wider.
The manufacturer reserves the right to construction or model modifications and/or alterations. Furthermore, the
right to any subsequent part modification and/or variations and amendments in procedures and standards due to
technical and engineering progresses in the art or due to environmental regulation changes, are also hereby
reserved.
2.6 Noise protection
Insulation figure of the construction of min. Rw = 57 dB
Walls which are bordering the parking lifts must be done as single wall and deflection resistant with min. m = 300 kg/ m²
Solid ceiling above the parking lifts with min. m = 400 kg/ m²
At differing constructional conditions additional sound absorbing measures are to be provided by the customer
The best results are reached by separated sole plates from the construction.
2.7 Protection against corrosion
Independent of a maintenance working has to be carried out regularly according to Surface Cleaning and
Protection mentioned in chapter 8 of this manual.
Clean up galvanized parts and platforms of dirt and road salt as well as other pollution (corrosion danger)!
2.8 Fire safety
Each and every fire safety requirement and all possible mandatory item(s) and equipment(s) (fire extinguishing
systems and fire alarm systems, etc.) are to be provided by the customer.
2.9 Railings
If walkways are arranged directly to the side or behind the lifts, railings have to be provided acc. EN ISO 13857 by
client acc. to local requirements, height min. 2000mm.
(5) Width dimensions