RoadRunner
U S E R S G U I D E
71
If you have been given only one SPID
number, enter this number for the first ‘B’
channel only.
5ESS, Custom:
If you service provider says you have
‘Custom ISDN’, you can have ‘point-to-
point’ or ‘point-to-multipoint’. In either
case, set the switch type to 5ESS Custom.
5ESS, National or Custom, version 5E9.1:
1 +
area code
+ phone
number dialing is required for all calls,
including local.
DMS-100, National ISDN: SPID numbers are always used and begin
with the area code + 7 digit number. The
SPID number may end with ‘00’, ‘01’, ‘0100’
or other suffix. Enter the SPID number as
provided by your service provider, do not
put a ‘1’ in front of the SPID number. Select
NI1 as the switch type.
In any of the above cases, if SPID numbers are used, ID numbers are
also used. You must use a seven-digit ID number when using a
TA201/TA301.
Very early versions of the TA201/301 did not support 56 kb/s
operation. MUSICAM USA will be happy to upgrade any of these early
units if you require 56 kb/s connectivity.
Control Problems
Symptom
Possible cause
Solution
Keypad not
responding
1.
Reset to factory defaults
Not responding to
remote terminal
control
—
Improper cable.
—
Incorrect port setting.
—
Incorrect protocol mode.
1. Use standard RS232 cable
1. Check settings match terminal
or computer.
1. Insure RS232 protocol is ‘OFF’
for terminal control, ‘ON’ for
program control.
“Arguments Bad”
—
Incorrect number of
1. Check command syntax