RoadRunner
U S E R S G U I D E
29
Terminal Adapter TA201/TA301 Software Version
From time to time, the TA201/TA301 terminal adapter software may be
enhanced as features are added. Upgrading software is as simple as
replacing a ROM chip on the terminal adapter. To determine the current
ROM version, use the sequence
<TAx01><Setup><country><Version>
or use the
VER
command.
Using TA Configuration Memory
The
RoadRunner
has the capability to store and recall up to 20 different
TA configurations. This feature is ideal if you use your
RoadRunner
from multiple locations. For example, once you have set up a TA for
use in a particular venue, you have only to recall that setup the next
time you return to that venue.
All relevant parameters are saved: TA type, country, switch type, SPID
and ID numbers, local check values, sub addresses, etc.
Saving Current TA Configuration
To save the current TA configuration, use the keypad sequence:
<
TA Type
><Save>.
Where
TA Type
is the installed terminal adapter type, either TA101,
TA201 or TA301.
When prompted, use the keypad to enter a descriptive name and press
ENTER
. From a terminal or computer, use the
CTE
command and enter a
descriptive name. In either case, the
RoadRunner
will return an ID
number for later recall.
Loading Stored Configurations
To recall a previously stored TA configuration, use the keypad
sequence
<
TA Type
><Recall>
to view the stored table using the keypad left and right arrow keys. A
sample display is shown here: