36
All addresses are shown as module configured with no jumpers (Offset = 0)
Name
Data Type
Byte
Bits
Description
Command
Byte
1
Command for index pointer (which message you’re sending)
Ctrl Mode Reset
2 bit
2
1,2
Enables Controller Mode Output Reset
Enable Status 1
Msg
3,4
Enables the constant transmission of status message 1
Enable Status 2
Msg
5,6
Enables the constant transmission of status message 2
Enable Amp Msg
7,8
Enables the constant transmission of amperage messages
Enable 24V DC
3
1,2
Enables the low and over voltage fault limits for 24V DC system
Save Configuration
3,4
Saves the configuration to the module (otherwise changes only valid until a power cycle occurs),
set to 1 to write configuration to module
Analog raw value
5,6
Sets all analog to be read in raw value as opposed to scaled ( .005668/bit)
7,8
4
1,2
3,4
5,6
7,8
FREQ1
Word
5
Sets the configuration of the frequency for all channels (30-1140 Hz)
6
MODE1
4 Bit
7
Not used on this module
MODE2
7
Sets the configuration of the inputs (0=Mode 2 Not USed, 1=Digital Postive, 2=Digital Ground)
No analog
ID1
Byte
8
User defined byte for configuration ID, this will be transimitted in the STAT message.
J1939 Output Configuration 1
6. MESSAGE STRUCTURE
PGN
61408 (0xEFE0) Node offset of 0
Source Address
(0x?? (CSA*))
PDU Format
239 (0xEF)
PDU Specific
224 (0xE0)
Built Message
(0x
18EFE0??
)
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Value
82 (0x52)
*CSA = Controller Source Address