A Murrelektronik Company
23
PGN
65307 (0xFF1B)
Source Address
224 (0xE0)
PDU Format
255 (0xFF)
PDU Specific
27 (0x1B)
Built Message
(0x
18FF1BE0
)
Name
Data Type
Byte
Bits
Description
Hertz_Count Input 7A
Word
1
Low Byte
Input 7A,
Hertz is used when the input is configured as a frequency input,
Count is used when the input is configured as a high speed counter
2
High Byte
Duty Cycle_ SP Input 7A
Word
3
Low Byte
Input 7A,
Duty Cycle is used when the input is configured as a frequency input,
Set Point is used when the input is configured as a high speed counter
4
High Byte
Hertz_Count Input 8A
Word
5
Low Byte
Input 8A,
Hertz is used when the input is configured as a frequency input,
Count is used when the input is configured as a high speed counter
6
High Byte
Duty Cycle_SP Input 8A
Word
7
Low Byte
Input 8A,
Duty Cycle is used when the input is configured as a frequency input,
Set Point is used when the input is configured as a high speed counter
8
High Byte
2. The Hertz and Duty Cycle are shown in the message below
Value
84 (0x54)
Name
Data Type
Byte
Bits
Description
Command
Byte
1
Command for index pointer (which message your sending)
INMODE8A
4 bit
2
1,2,3,4
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground,
0x7=Digital Positive Frequency
,
0x8= Counter
INMODE8B
4 bit
2
5,6,7,8
Mode 0x0=disabled, 0x1=Digital Positive, 0x2=Digital Ground, 0x3= 4-20ma (4000-20000),
0x4= 0-5V DC (0-5000, 0x5= 0-10V DC (0-10000), 0x6= 0-32V DC (0-32000),
0x9= Ratiometric (0-100.0% of source V DC)
Byte
3
Not Used on This Module
4
5
6
7
8
A Murrelektronik Company