A Murrelektronik Company
15
CAN Ports 1 & 2 Non-Isolated
Power (Module and Input, 13A)
Pin 1 = 8-32V DC
Pin 3 = Ground (A)
CAN
1
2
4
3
6
5
7
8
1 2
4 3
Module and
Input Ground(A)
CAN High
CAN Low
Module and
Input Power
5.2 INPUT CONFIGURATION
5.2.1 POWERING THE INPUTS
Please note that module and input power is
provided via the CAN port
All Ground (A) connections are internally
connected and are isolated from Ground (B)!