WARNING!
BEFORE USING THE HEATER CAREFULLY READ THIS
MANUAL AND KEEP IT FOR FURTHER READING.
1. GENERAL SAFETY
For your safety it is recommended to follow the
precautions listed below:
DO NOT use the heater in explosive
environments, or where gas or flammable
vapours can be found.
Ensure a clearance of at least 1 m from
flammable materials, walls, ceilings or any
other object:
DO NOT COVER. DO NOT BLOCK THE AIR
INLET AND OUTLET.
DO NOT USE in bathrooms, showers, near
swimming pools and wet environments.
Only install in upright steady position.
DO NOT use the heater if protection guards
or external panels are not mounted.
DO NOT TOUCH THE SURFACES OF THE
UNIT DURING OPERATION AND FOR AT
LEAST 10 MINUTES AFTER SHUT DOWN.
BURN DANGER !
DO NOT use if any parts are broken or
damaged (heating elements, fan, etc.)
Shut down and unplug the unit before
handling, moving or cleaning it.
DO NOT expose the power cable to heat.
Frequently check the power cable: should it
be damaged, have it replaced by qualified
personnel.
2. CONNECTION TO MAINS
SINGLE-PHASE MODELS 230 V 50 Hz (2 kW - 3.3
kW)
These models are supplied with a power cable and
plug and must be connected to a 230V 50Hz
grounded electrical outlet.
WARNING ! GROUNDING IS MANDATORY
THREE-PHASE 400 V 3 50 Hz MODELS (5 kW - 9 kW
- 15 kW - 22 kW)
These models are supplied with a three-phase plug
on the heater and a trailing socket for the
connection to a three-phase electrical system
(R,S,N,T) 400V 3 50Hz. The power cable is not
supplied.
WARNING ! GROUNDING IS MANDATORY
WARNING ! CONNECTION TO MAINS MUST BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
The electrical system to which the unit is connected
must comply with safety regulations. It is
recommended that a residual current circuit
breaker is installed in the electrical system.
3. USE
START UP – HEATING
Make sure to have properly installed and
connected the heater.
Turn the power selector to the desired
setting.
Turn the room thermostat knob to the
desired setting.
Note: if the room thermostat is set on a
temperature lower than room temperature, the unit
will not heat. Should this occur, turn the room
thermostat knob to a higher temperature.
SUMMER VENTILATION
To use the heater as a ventilator turn the power
selector on the “fan” position
.
SHUTDOWN
FAN STOP models 2 kW , 3kW, 3.3 kW , 5 kW
Turn the power selector on position
(fan) for
about 2 minutes to allow the unit to cool down.
Turn the power selector to 0 (OFF) to shut the
heater down completely.
POST-VENTILATION models 9 kW, 15 kW, 22 kW
Turn the room thermostat knob to the minimum
position. The fan goes on rotating for 3-4 minutes
to allow the heater to cool down and then it will
Summary of Contents for RPL