17
|
© Munters AB, 2018
Fig.12
Assembly flex fittings installed in buildings with
wooden rafters.
WARNING
Attach the suspension arm loosely so that the weight pulls it to the vertical position, then tight the
bolts.
5.6 Installation of complete motor fixture including motor
Fig.13
As shown in Fig.13, the gear motor and motor fixture are
available as a complete unit. The eye nuts shown are
used for 4 x wire attachment. The attachment equipment
makes up part of the Breeze Fan’s stabilizing/safety
equipment.
Fig.14
Suspension arm tightened (must be vertical).
Fig.15
Fit the suspension arm to the complete motor fixture by
means of 3 screws M12, 6 washers Ø12 and 3 self-locking
nuts M12 (tightening torque 90 Nm).