11
|
© Munters AB, 2018
4. OPERATING CONDITIONS
Circulation fans, such as the Breeze Fan, are products to be used to circulate the air inside a structure, thereby creating
air movement inside the structure which helps to cool animals down during hot periods.
Normal ambient temperature limits are -15°C to +40°C. Maximum altitude is 1000 m above sea level. If a fan is required
to operate at a higher altitude, the loss in mass flow (heat removing capacity) due to lower air density should be taken into
consideration.
The Breeze Fan is quite heavy (see chapter 7.2), so before lifting and handling it must be checked that the necessary,
suitable equipment is available.
USES EXPLICITLY EXCLUDED
The Breeze Fan is NOT made and therefore must absolutely NOT be used for other purposes such as (not exhaustive
list):
•
Use in atmospheric conditions even only potentially explosive
•
Use in aggressive atmospheric conditions
•
Use in atmospheric conditions with high salinity or humidity over 90% of that of the standard atmospheric air
•
Use in places in which external suspended elements are present (for example, fibres, powders, paints, sand)
•
Use in outside environments
•
Use in places that subject the product to vibrations or oscillations
•
Precarious and temporary use