MENU
n11
n14
n15
n16
n17
n18
n21
n22
n25
n27
n31
n32
n33
n35
n41
n42
n43
n44
n45
n46
n47
Release emergency stop
Power limitation mode 1 (100%, default)
Power limitation mode 2 (90%)
Power limitation mode 3 (80%)
Power limitation mode 4 (70%)
Power limitation mode 5 (60%)
Power limitation mode 6 (50%)
Power limitation mode 7 (40%)
Description
Test operation
Cooling test
Heating test
Maintenance mode
Manual defrost
Automatic refrigerant diagnosis
Refrigerant recovery 1 (PUMP DOWN)
Refrigerant recovery 2 (PUMP OUT)
Auto refrigerant charging
Vacuumizing mode
Last fault code
Clear fault history
Fan software version
Note
nC3
nC4
nC5
nC7
nE1
nE2
nE3
Start address for automatic addressing
Assign indoor unit addresses automatically
Display the online IDU address
Clear IDU address and MS address
Refrigerant leakage protection function 1
Refrigerant leakage protection function 2
Refrigerant leakage protection function 3
Note
Restore factory default of menus.Valid
for the master unit. (Except when
snow-proofing and reverse rotation for
dedusting)
n34
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
nC2
nC2=0
:
Remote shut down setting #1:
System stops when the circuit (R-OFF1)
is 'short'(default)
nC2=1
:
Remote shut down setting #2:
System stops when the circuit (R-OFF1)
is 'open'
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
1
2
3
4
5
Only available for master unit
Only available for master unit (Te target temperature
during cooling operation, Automatic control)
Only available for master unit (Te target temperature
during cooling operation, Locking)
Only available for master unit (Tc target temperature
during heating operation, Automatic control)
Only available for master unit (Tc target temperature
during heating operation, Locking)
Auto regulation of medium capacity
(Tes0=6,default)
Auto regulation of medium capacity
(Tcs0=48,default)
n91
n92
n93
n94
n95
n96
n97
n98
Auto regulation of high capacity (Tes0=3)
Auto regulation of low capacity (Tes0=9)
Low locking capacity (Tes0=9)
Medium-to-low locking capacity (Tes0=6)
Medium locking capacity (Tes0=3)
Medium-to-high locking capacity (Tes0=0)
High locking capacity (Tes0=-3)
nA1
Auto regulation of high capacity (Tcs0=50)
Auto regulation of low capacity (Tcs0=45)
Low locking capacity (Tcs0=42)
Medium-to-low locking capacity (Tcs0=44)
Medium locking capacity (Tcs0=46)
Medium-to-high locking capacity (Tcs0=48)
High locking capacity (Tcs0=51)
Fahrenheit degree setting(
đ
)
Celsius degree setting(
℃
)(default)
Auto snow-blowing 1
Auto snow-blowing 2
Exit auto snow-blowing mode(default)
Setting of the VIP IDU address
nA2
nA3
nA4
nA5
nA6
nA7
nA8
nb1
nb2
nb5
nb6
nb7
nb8
nC1
Reverse rotation for dedusting. When
this function is activated, ddOn is
displayed. When this function is
disabled, ddOF is displayed.
MENU Description
nC2
32