RPR 583
TM1212 Issue 1
Page 1 - 3
1.3
SPECIFICATIONS
1.3.1
Receiver Performance
Frequency Range:
430 MHZ through 470 MHZ
Frequency Bands:
Band 1:
430.000 MHZ - 434.999 MHZ
Band 2:
435.000 MHZ - 439.999 MHZ
Band 3:
440.000 MHZ - 443.999 MHZ
Band 4:
444.000 MHZ - 446.999 MHZ
Band 5:
447.000 MHZ - 450.999 MHZ
Band 6:
451.000 MHZ - 456.999 MHZ
Band 7:
457.000 MHZ - 462.999 MHZ
Band 8:
463.000 MHZ - 469.999 MHZ
Channel Spacing:
25kHz
Intermediate Frequencies:
45MHz and 455kHz
Crystal Frequencies (except Band 4):
Local Oscillator:
Carrier Frequency - 45MHz
3
2nd Oscillator:
44.545MHz
Band 4:- 45.455MHz
Sensitivity:
The sensitivity figures quoted in Table 1 assume an ambient temperature in the
range 18
E
C through 25
E
C. The battery voltage should be above the low battery
trigger point of approximately 1.15 volts. At temperatures between the ambient and
maximum / minimum, performance is at an intermediate value. At temperature
extremes degradation of sensitivity shall not exceed 6dB.
Table 1.1: Sensitivity Figures
MEASUREMENT
MODE
BEST
POSITION,
GUARANTEED
MINIMUM
BEST
POSITION,
TYPICAL
TEM CELL
(dBm),
TYPICAL
On Pole
27 dBµVm
20 dBµVm
-105 dBm
-1
-1
Summary of Contents for RPR 583
Page 6: ...RPR 583 TM1212 Issue 1 Page vi INTENTIONALLY BLANK...
Page 12: ...RPR 583 TM1212 Issue 1 Page 1 6 INTENTIONALLY BLANK...
Page 32: ...RPR 583 TM1212 Issue1 Page 2 20 INTENTIONALLY BLANK...
Page 42: ...RPR 583 TM1212 Issue 1 Page 3 10 INTENTIONALLY BLANK...
Page 44: ...RPR 583 TM1212 Issue 1 Page 4 2 INTENTIONALLY BLANK...
Page 72: ...RPR 583 TM1212 Issue 1 Page 5 28 INTENTIONALLY BLANK...
Page 82: ...RPR 583 TM1212 Issue 1 Page 6 10 INTENTIONALLY BLANK...
Page 84: ...RPR 583 TM1212 Issue 1 Page 7 2 INTENTIONALLY BLANK...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......