90
Chapter 5 - Commands
6.1
Introduction
The following procedures assume that your MultiMuxes (local and
remote) have been installed properly and the appropriate channel
devices have been connected to each channel.
6.2
MultiMux Operating Procedures
The MultiMux operating procedures cover entering parameters for both
your local and remote MultiMux units.
Table 6-1. MultiMux Operating Procedures
Channel
1
Turn power on to your MultiMux and supervisory console, type AT
and then hit Return. If you get an OK message back, you are
communicating with the command port.
2
Execute the parameter display command to display current channel
parameter status for your local MultiMux by entering the following:
ATL (hit Return)
The following will be displayed on your supervisory console:
Local Channel Parameter
STP
FLOW
ENQ/
PASS
PASS
CHN
SPD
WORD BIT
PARITY
CONTROL
ACK
ECHO PACE
EIA
XON
01
19200 8
1
NONE
XON/XOFF
OFF
OFF
OFF
OFF
OFF
02
19200 8
1
NONE
XON/XOFF
OFF
OFF
OFF
OFF
OFF
03
19200 8
1
NONE
XON/XOFF
OFF
OFF
OFF
OFF
OFF
04
19200 8
1
NONE
XON/XOFF
OFF
OFF
OFF
OFF
OFF
If your MultiMux is communicating with a MultiMux MM16/32 and the
4-position DIP-Switches SW-1 and SW-2 are open, the following
screen is displayed . The channel numbers shown in the chart will
be the same as those virtual channel numbers selected by the 8-
position DIP switch SW-6, SW-7 and SW-8. A new column (DEST)
is added when communicating with a MM16/32 or MMH16/32.
Destination channel is set with the DC command.
Summary of Contents for MMH900
Page 1: ...MMH900 Series Statistical Multiplexer User Guide...
Page 7: ...Chapter 1 Introduction Description...
Page 26: ...Chapter 2 Configuration...
Page 33: ...Chapter 3 Front Rear Panel Descriptions...
Page 44: ...Chapter 4 Installation...
Page 51: ...Chapter 5 Commands...
Page 89: ...Chapter 6 Operating Procedures...
Page 96: ...Chapter 7 Troubleshooting...
Page 111: ...Chapter 8 Service Warranty Technical Support...
Page 116: ...Appendices...
Page 184: ...Glossary...
Page 193: ...Glossary 193 X Y Z...
Page 200: ...S000315A...