background image

KUBOTA WATER HEATER KIT INSTRUCTIONS (MULTI-MODELS) P/N 14254 — REV. #0 (12/14/15) — PAGE 3

COOLANT DRAINING

1.  Locate and place a clean container below the coolant 

drain port (Figure 5) to catch drained coolant. The 

collected coolant will be reused later. Make sure no 

foreign particulates or contaminates are present in 

the drained coolant.

2.  Using an open-ended wrench, remove the coolant drain 

plug and drain approximately 1/2-3/4 gallons of coolant 

(Figure 5) from the coolant reservoir.

Figure 5. Coolant Drain Plug Removal

FREEZE PLUG REMOVAL

1.  Before accessing freeze plug on the engine block, 

make sure to cover the generator (Figure 6) and other 

nearby components with an absorbent material to catch 

any excess coolant.

Figure 6. Covered Generator

 NOTICE

This will lower the coolant level below the base of the 

cylinder head.

COOLANT

DRAIN

PLUG/PORT

COVERED GENERATOR

2.  Locate the freeze plug (Figure 7) on the engine block.

Figure 7. Engine Block Freeze Plug

3.  Using a 6"-8" punch and hammer, tap one edge of the 

freeze plug (Figure 8) until it becomes loose or offset 

from its original set placement.

Figure 8. Freeze Plug Loosening

4.  Using channel locks, remove the freeze plug from the 

engine block as shown in Figure 9.

Figure 9. Channel Lock Freeze Plug Removal

FREEZE

PLUG

FREEZE

PLUG

6”-8” PUNCH

AND HAMMER

FREEZER

PLUG

CHANNEL

LOCK

Reviews: