MQ SP-3035 CONCRETE SAW — OPERATION AND PARTS MANUAL — REV. #3 (09/29/06) — PAGE
52
MQ SP-3035 CONCRETE SAW
Engine Maintenance
The Model SP-3035 uses a 35 HP Wisconsin engine. See the engine manual for service details.
Check air filters daily. Do not clean. Replace as needed. See Caution below.
Check engine oil level daily.
Level the saw frame prior to service to get accurate readings.
Change the engine oil and filter every 50 hours of operation.
Filters
Filter
Qty Part Number & Cross Reference
Primary Air Filter
1
300000-1
Safety Air Filter
1
300000-2
Engine Oil Filter
1
306004
Hydraulic System Filter
1
306006
Inline Fuel Filter
1
304000
DANGER
Safety Air Filters are
NOT
intended to be used for primary air
filtration. When the Primary Filter becomes clogged, replace it
immediately –
DO NOT run saw using just the Safety filter.
DO NOT attempt to clean dirty air filters by any means.
Fig. 39 — Filters
Transaxle
filter
Engine
Oil filter
Air filter
Hydraulic Oil
Reservoir
Fuel filter
Summary of Contents for Diamond Back SP3 Street Pro