30
Part Number: 9290312 October/22/2018
11. Unit will automatically run through the cleaning/
sanitizing process.
12. Towards the end of cleaning /sanitizing process there will
be a system purge process and once bubbles are seen
coming from five (5) gallon bucket, close plain coffee tap.
13. Once cleaning /sanitizing process is complete the LED
will not be illuminated, which indicates cleaning is
complete and both product taps can now be closed.
NOTE: To abort cleaning mode at any time press and hold
the cleaning button until the LED around the Prime/Clean
button turns OFF. This exits cleaning mode into keg change
mode and LED will no longer be illuminated.
NOTE: Priming is required after aborting cleaning or
clearing an error.
See “Priming the System” on page 20
Imprtant
If cleaning mode is accidentally aborted or aborted because
of an issue/reason, then the cleaning process will need to
start over from the beginning after a two (2) minute wait.
NOTE: If an error is encountered at any time during cleaning
process the cleaning button will blink ON/OFF rapidly
indicating unit is in an error state and cleaning process has
stopped.
See “Clearing Error Code” on page 20.
14. Disconnect cleaning keg and set aside.
15. Disconnect clear drain hoses from tap nozzles, empty
five (5) gallon bucket and store for use during next
weekly cleaning.
Imprtant
Kegs used for cleaning & sanitizing solutions should be
emptied and cleaned before reuse.
Clean n‑line Strainer
16. Once the cleaning/sanitizing is complete the strainer
will need cleaned again to ensure no new debris have
been trapped in the filter.
17. De-pressurize the system.
See “Clean In-line Strainer” on page 27.
18. Reassemble the bowl with mesh and gasket back in place.
19. Complete all other weekly cleaning tasks before