Part Number: 9290312 October/22/2018 29
LEVEL 2 - WEEKLY CLEANNG (SNGLE STEP METHOD)
Imprtant
One of the Level 2 methods is to be performed daily on
the Milk line.
NOTE: Only to be performed using KAY-5® Sanitizer/Cleaner,
if KAY-5® Sanitizer/Cleaner is not available the three step,
Clean, Rinse, Sanitize method must be performed.
Weekly Cleaning (Three Step Method)” on page 31
1. Approved Sanitizer / Cleaner.
APPROVED CLEANER/SANITIZER
• KAY-5® Sanitizer/Cleaner mixed one (1) packet in
2.5 gallons (9.5L) of lukewarm water to equal 100
ppm chlorine. This sanitizer / cleaner is compatible
with equipment metals and materials.
NOTE: The cleaner / sanitizer must provide 100 ppm chlorine,
use the provided 2.5 (9.5L) measuring bucket to ensure
proper ratio.
n
Warning
Powdered cleaners and sanitizers must be thoroughly
mixed into water/solution to prevent crystals from
remaining and causing damage to system components.
Make sure one (1) properly cleaned and sanitized cleaning
keg is available to perform proper weekly cleaning.
“Manual Keg Cleaning” on page 25 & “Level 3 - Monthly
Cpffee Delivery SysteI Cleaning & Sanitizing
1. Disconnect coffee keg and set aside.
Clean n‑line Strainer
2. De-pressurize the system.
then
See “Clean In-line Strainer” on page 27.
Bowl
3. Reassemble the bowl with mesh and gasket back in place.
Cleaning the SysteI
4. Mix proper concentration of KAY-5® Sanitizer/Cleaner
solution in the three (3) gallon cleaning keg with warm
tap water.
5. Connect the outlet (OUT) then inlet (IN) keg connectors
cleaning solution keg.
6. Press and release the Prime/Clean button to prime
the system with cleaning/sanitizing solution. The LED
around the button will flash ON then OFF.
Prime/Clean
Button
Sanitizing
Keg
Cleaning
Hoses
5 Gallon
Bucket
7. Place a clean five (5) gallon bucket on the floor in front of unit.
8. Place clear nozzle cleaning hose over nozzles of both the
(plain and nitrogen coffee) taps and place other end of clear
hoses in the five (5) gallon bucket.
9. Open both the plain and nitrogen coffee taps.
10. Press and hold the Prime/Clean button until the LED around
the button turns on to place the unit into cleaning mode.
NOTE: Cleaning button will illuminate blue in color around the