background image

www.modellmarkt24.ch

 

Operating Instructions RX-6-DR light M-LINK / 

 

RX-7-DR light M-LINK 2.4 GHz receiver 

Page 7 

Instru

ctions: RX-6/7-DR l

ight M-L

INK 

2.4 

GHz re

ceiver #

 82 5490

 (09-

07-16

/MIWA) 

 •

  Er

ror

s

 an

d omission

s excep

ted! 

 •

  

©

 M

U

LT

IPL

E

X

 

!

 

These operating instructions are an integral part 

of the product, and contain important information 
and safety notes. Please store them in a safe place, 
where you can find them at any time, and pass 
them on to the new owner if you sell the receiver. 

1.

 

S

PECIFICATION

 

 

RX-6-DR light 

M-LINK

 

RX-7-DR light 

M-LINK

 

Order No. 

# 5 5809 

# 5 5810 

Reception system 

2.4 GHz FHSS M-LINK 

Frequency Hopping Spread Spectrum

MULTIPLEX-LINK 

Servo channel count 

6 7 

Servo signal frame 
rate 

Fast response: 14 ms 

Standard: 21 ms 

Signal resolution 

12-bit, 3872 steps 

Current drain 

Approx. 10 mA (excl. servos) 

Aerial feed length /  
aerial length 

Feed cable: approx. 10 cm (2 x) 

Aerial: approx. 3 cm (2 x) 

Operating voltage 

3.5 V … 9.0 V 

Î

 4 - 6 NiCd / NiMH cells (NiXX) 

Î

 2S LiPo / LiIo 

Operating  
temperature range 

- 20

 

°C … + 55

 

°C 

Weight 

10 g 

Dimensions 

Approx. 38.0 x 28.0 x 11.5 mm 

 

2.

 

S

PECIAL 

F

EATURES

 

  Small, all-purpose 6-channel / 7-channel receiver exploiting 

MULTIPLEX 2.4 GHz M-LINK technology, ideal for use in 
small models. 

 Dual 

receiver: 

The receiver contains two complete receiving circuits which 
operate in parallel (receiver diversity).  
This provides excellent reception quality by minimising 
directional effects. 

  In-line connector arrangement: 

Ideal for use even in slender fuselages (e.g. F3B, F3J, …). 

  HOLD / FAIL-SAFE function. 

  Integral SET button and LED:   

For binding, FAIL-SAFE programming, RESET and 
operating status information. 

3.

 

S

AFETY 

N

OTES

 

!

 

Please read the instructions before using the receiver. 

!

 

Use the receiver only for the intended applications  
(

Î

 4.). 

!

 

Ensure the power supply is of adequate capacity (

Î

 6.).

 

!

 

Observe the installation notes (

Î

 9.).

 

!

 

Carry out regular range checks (

Î

 10.).

 

4.

 

A

PPLICATION

 

The

 

RX-6/7-DR light M-LINK

 is a radio control receiver inten-

ded exclusively for use in model sport applications. It is prohi-
bited to use it for other applications, such as man-carrying 
vehicles or industrial installations. 

The 

RX-6/7-DR light M-LINK

 was designed with minimum 

possible size and weight as top priority, and for technical rea-
sons such a unit cannot offer the same reception characteristics 
as a larger, technically more sophisticated and more expensive 
receiver. In the interests of safety we recommend that you use a 
larger receiver wherever space permits. However, under normal 
conditions it is possible to obtain an excellent reception perfor-
mance with the 

RX-6/7-DR light M-LINK

 provided that all the 

RC components are arranged carefully, and the two receiver 
aerials are deployed correctly.

 

5.

 

C

OMPATIBILITY

 

The 

RX-6/7-DR light M-LINK

 2.4 GHz receiver can only be used 

in conjunction with transmitters which use MULTIPLEX M-LINK 
transmission technology. As of June 2009 these are: 

 

ROYALpro 7

9

 and 

16 M-LINK

 

ROYALevo 

or

 pro 7

9

 and 

12

 with firmware version V3.xx 

and the HFM4 M-LINK 2.4 GHz RF module. 

 

PROFImc 3010

3030

 and 

4000

 with the HFM3 M-LINK  

2.4 GHz RF module. 

 

COCKPIT SX M-LINK

 

MULTIPLEX transmitters

 with the HFMx M-LINK 2.4 GHz 

RF module. 

6.

 

P

OWER 

S

UPPLY

 

The 

RX-6/7-DR light M-LINK

 receiver works with a wide range 

of voltages from 3.5 V … 9.0 V, i.e. with receiver batteries con-
sisting of 4 to 6 NiXX cells or 2S LiPo / 2S LiIo batteries. 

!

 Note: 

if you wish to use a five-cell (six-cell) NiXX battery, 

check that all the servos, gyros and other components to be 
connected to the system are approved by the manufacturer for 
use on operating voltages up to 7.5 V (9.0 V). If you wish to use 
a 2S LiPo (2S LiIo) pack, check that all the servos, gyros and 
other components to be connected to the system are approved 
by the manufacturer for use on up to 8.4 V (8.2 V). 

!

 

Note: ensure that the power supply is adequate

 

A power supply system in good condition and of adequate 
capacity for the specific application plays an indispensable role 
in the safe operation of any model: 

  Use only high-quality receiver batteries of adequate capacity. 

Balance and maintain them carefully, and charge them fully. 

  Ensure that all cables are of adequate conductor cross-

section. Keep all wiring as short as possible, and use the 
absolute minimum of plug / socket connections. 

  Use high-quality switch harnesses exclusively. 

  Brief collapses in the power supply voltage (lasting a few 

milli-seconds) have no adverse effect on the receiver. Longer 
voltage collapses to below 3.5 V may cause a receiver reset, 
resulting in a brief interruption in reception. This may be due 
to a receiver battery which is almost flat, too weak or defec-
tive, cables of inadequate cross-section, poor-quality con-
nectors or an overloaded or defective BEC system. 

 

 

 

 

 

 
 

www.modellmarkt24.ch

Summary of Contents for M-LINK Series

Page 1: ...75015 Bretten MULTIPLEX 2009 Printed in Germany www multiplex rc de Bedienungsanleitung 3 6 Operating Instructions 7 10 Notice d utilisation 11 14 Istruzioni per l uso 15 18 Instrucciones 19 22 RX 6 D...

Page 2: ...www modellmarkt24 ch www modellmarkt24 ch...

Page 3: ...ngseigen schaften eines gr eren technisch aufw ndigeren und teureren Empf ngers aufwarten berall dort wo ein gr erer Empf nger untergebracht werden kann sollte dieser aus Sicherheits gr nden verwendet...

Page 4: ...Frankreich Mode umgestellt werden Wenn der Empf nger mit einem anderen M LINK Sender betrieben werden soll 8 2 1 Ablauf der Binding Prozedur 1 Zum Binding m ssen Sender und Empf nger in den Binding M...

Page 5: ...fen Verletzungsgefahr 8 5 RESET auf Werkseinstellungen Die Einstellungen des Empf ngers k nnen auf Lieferzustand Default Werte zur ckgesetzt werden Alle Ihre Einstellungen z B gebundener Sender FAIL S...

Page 6: ...rgung nicht in den Haus m ll geben sondern einem geeigneten Entsorgungs system zuf hren In L ndern der EU Europ ische Union d rfen Elektro ger te nicht durch den Haus bzw Restm ll entsorgt werden WEEE...

Page 7: ...acteristics as a larger technically more sophisticated and more expensive receiver In the interests of safety we recommend that you use a larger receiver wherever space permits However under normal co...

Page 8: ...t to France mode by repeating the binding procedure If the receiver is to be operated in conjunction with a different M LINK transmitter 8 2 1 Sequence of the binding procedure 1 The first step is alw...

Page 9: ...r settings can be reset to the factory default values if you wish If you do this please note that all your settings e g bound transmitter FAIL SAFE settings will be lost Hold the SET button pressed in...

Page 10: ...ste instead it should be taken to a suitable specialist disposal system In the countries of the EU European Union electrical equipment must not be discarded via the normal domestic refuse system WEEE...

Page 11: ...K tant con u pour avoir les plus petites dimensions possibles ainsi qu un poids r duit au maximum ne peut pas rivaliser avec les plus gros r cepteurs qui sont plus sophistiqu s et plus chers Pour des...

Page 12: ...s de Binding avec le r cepteur afin qu il passe galement en mode France Lorsque le r cepteur doit tre utilis avec un autre metteur M LINK 8 2 1 D roulement de la proc dure Binding 1 Pour effectuer l o...

Page 13: ...stivement danger de blessure 8 5 RESET pour passer en r glage d usine Vous avez la possibilit de recharger les param tres en sortie d usine sur le r cepteur valeurs par d faut Tous vos r glages seront...

Page 14: ...poubelle barr e ne doivent pas tre jet s dans une poubelle traditionnelle mais apport s au point de recyclage le plus proche Dans les pays de l union europ en EU il est stricte ment interdit de jeter...

Page 15: ...le prestazioni di ricezione di una ricevente pi grande tecnicamente pi complessa e pi costosa Per motivi di sicurezza quando lo spazio d installa zione lo consente si consiglia in ogni caso l impiego...

Page 16: ...le radio M LINK possono essere impostate nella cosid detta modalit francese dopodich necessario effettuare nuovamente il Binding per attivare la nuova modalit anche sulla ricevente Se la ricevente vie...

Page 17: ...a ricevente possono essere ripristinate a quelle di fabbrica valori Default Tutte le impostazioni p es radio sincronizzata posizioni FAIL SAFE andranno perse Premere il tasto SET per almeno 10 secondi...

Page 18: ...elettrici contrassegnati con il bidone della spazzatura depennato non possono essere smaltiti nella normale spazzatura di casa ma devono essere riciclati opportunamente Nei paesi UE Unione Europea gl...

Page 19: ...el menor tama o y el peso m s ligero posible no pueden esperarse las mismas capacidades de recepci n de un receptor tecnicamente m s complejo y de mayor tama o y precio Siempre que se pueda utilizar u...

Page 20: ...bajar en el modo denominado Modo Francia A con tinuaci n tambi n debe volver a asociarse el receptor para que pase a trabajar en Modo Francia Cuando el receptor deba ser controlado mediante otra emi s...

Page 21: ...ligro de lesiones 8 5 Volver a los valores de f brica RESET La configuraci n del receptor puede inicializarse con los valores de f brica por defecto Todos los ajustes P ej emisora asociada posiciones...

Page 22: ...a cruz no deben ser arrojados a la basura normal sino que se han de depositar en un contenedor para su reciclaje En los pa ses de la UE Uni n Europea los disposi tivos el ctricos electr nicos no deben...

Reviews: