9.2  The functions of the SET button 

Pressing the SET button on the top of the receiver when 
switching on initiates the binding process (

Î

9.3.1

). 

In receive mode, the SET button can be used to trigger two addi-
tional functions. The function selected depends on the length of 
the button-press:  

 1. 

Save error counter or FAIL-SAFE settings

 

Press the SET button for 0.5 to 1 second (

Î

 9.8

 and 

Î

 9.5

).

 2. 

RESET receiver to factory default settings

 

Press the SET button for longer than ten seconds (

Î

9.6

).

When the SET button is pressed, the STATUS LED generates 
time markers corresponding to the length of the button press: 

Press SET 
button con-
stantly for 

< 2
seconds

2 to 10 
seconds

> 10  
seconds

STATUS-LED  

OFF ON OFF 

Purpose 

Save error 
counter /  
FAIL-SAFE 
settings 

 RESET 

 

to default 
settings 

!

 Note: 

After the save process the STATUS LED flashes the confirma-
tion signal (LED code 5 

Î

 9.1

).

9.3 Binding 

The receiver must be set up to match the transmitter before the 
system can work. This process is known as “binding”. 

!

 Note: 

The signal output to the servo sockets is switched off during the 
binding procedure. This means that the servos are “soft”, and do 
not move, while the motor connected to a modern electronic 
speed controller remains OFF due to the lack of a signal. Never-
theless, it is important to secure the model and keep well clear 
of the power system. 

The binding process is necessary in the following cases: 

x

  The first time the receiver is used (

Î

 9.3.1

).

x

  After a receiver RESET (

Î

 9.6

). 

x

  After the transmitter setting for “Fast Response” has been 

changed. For more information on this please refer to the 
operating instructions supplied with your M-LINK transmitter 
or M-LINK RF module. 

x

  After the transmitter setting for the frequency range has been 

changed. For more information on this please refer to the 
operating instructions supplied with your transmitter or M-
LINK RF module (“France mode”). 

x

  If the receiver is to be operated in conjunction with a different 

M-LINK transmitter. 

9.3.1 Sequence of the binding procedure 

1.  The first step is always to set the transmitter and receiver to 

Binding mode: 

x

  Place the transmitter and the receiver aerials close to-

gether. 

x

  Switch the transmitter ON in binding mode. 

 

(see the operating instructions supplied with your M-LINK 
transmitter or M-LINK RF module). 

x

 Switch 

the 

RX-9/12/16-DR pro M-LINK

 receiver ON in 

binding mode: 

x

  Use a pointed object to press and hold the SET button 

 

on the top of the receiver (

Î

 9.2

). 

x

   Switch the receiver ON, or connect the battery: 

Ÿ

  The binding procedure runs, the STATUS LED on 

the receiver flashes at high frequency   
(LED code 2 

Î

 9.1

). 

x

   Now release the SET button. 

!

 Note:

 the binding process starts automatically when 

the receiver is used for the first time, and after a RESET - 
even if you have not pressed the SET button. 

2.  Once the transmitter and receiver are bound to each other, 

both switch 

automatically

 to normal operation (

Î

 9.4

):

Ÿ

 The STATUS LED on the receiver flashes slowly 

 

 

(LED code 3 

Î

 9.1

). 

!

 Note: 

in most cases the binding process only takes a few 

seconds.

9.3.2  Binding: locating and correcting faults 

Fault:  

During the binding procedure the STATUS LED on the receiver 
continues to flash at high frequency for a few seconds. 

Cause:  

No M-LINK signal of adequate strength detected. 

Remedy: 

x

  Reduce the distance between your transmitter and the 

receiver aerials. 

x

  Ensure that your transmitter is switched ON in binding mode. 

x

  Repeat the binding procedure. 

9.4  Switching the receiver ON and OFF  

in normal operations 

9.4.1  Sequence of switching ON and OFF 

To switch the M-LINK RC system ON, please use this 
procedure: 

1.  Switch the transmitter ON. 

2.  Switch the receiver ON. 

The STATUS LED on the receiver flashes slowly and evenly 
(LED Code 3 

Î

 9.1

):  

Ÿ

  An M-LINK signal is being received, 

 

the RC system is ready for use. 

To switch the M-LINK RC system OFF, please use this 
procedure: 

1.  Switch the receiver OFF. 

2.  Now switch the transmitter OFF. 

9.4.2  Fault finding and fault correction when switching ON 
Fault: 

The STATUS LED on the receiver lights up continuously after 
switching on (LED code 1 

Î

 9.1

), but does not flash. 

Cause:

No M-LINK signal detected. 

Remedy: 

x

  Is the transmitter switched on? 

x

  Is the transmitter generating an M-LINK signal?  

x

  Are the transmitter and receiver bound to each other? 

x

  Have you carried out a receiver RESET (

Î

 9.2

,

Î

 9.6

)? 

x

  Have you made changes to the setting for “Fast Response” 

(

Î

 9.3

) or “France mode” (

Î

 9.3

)? 

!

 Note:

 if no M-LINK signal is detected when the receiver is 

switched on, the two LEDs RX1 and RX2 also glow a constant 
red. 

Summary of Contents for 5 5813

Page 1: ...ten MULTIPLEX 2010 Printed in Germany www multiplex rc de Bedienungsanleitung 3 10 Operating Instructions 11 18 Notice d utilisation 19 26 Istruzioni per l uso 27 34 Instrucciones 35 42 RX 9 DR pro M...

Page 2: ......

Page 3: ...ing FAIL SAFE Programmierung RESET und Betriebs Statusinformation x HOLD FAIL SAFE Funktion x Integrierter Fehlerz hler Datenlogger Spannungs und Signalfehler ber separate LED s direkt am Empf nger si...

Page 4: ...em Beim Anschlie en von Empf ngerakku Servos Regler Sensor auf korrekte Steckrichtung und insbesondere bei Fremdprodukten auf kompatible Kontaktbelegung achten siehe Symbole auf dem Empf nger Polarit...

Page 5: ...ie den Sender im Binding Modus EIN siehe Bedienungsanleitung Ihres M LINK Senders bzw M LINK HF Moduls x Schalten Sie den Empf nger RX 9 12 16 DR pro M LINK im Binding Modus EIN x SET Taste auf der Ob...

Page 6: ...tellungen zu einem m glichst unkritischen Zustand des Modells f hren z B Motor in Leerlauf E Motor AUS Ruder neutral Landeklappen ausfahren Schleppkupplung ffnen FAIL SAFE Stellungen setzen 1 Die LEDs...

Page 7: ...dem Modell zur ck zum Sender zu bertragen Beim Einsatz dieser Empf ngertypen werden die telemetrischen Werte Empf ngerakku Spannung und Verbindungsqualit t LQI Link Quality Indication direkt und ohne...

Page 8: ...en 20 Skizzen A D x Stromf hrende Kabel wie z B von Regler Motor und An triebsakku so kurz wie m glich halten x PeakFilter 8 5180 bei Einsatz von Dioden Akkuweichen verwenden x Die Empfangsqualit t l...

Page 9: ...en Verwendung unbedingt einer sorgf ltigen Funktionskontrolle Senden Sie den Empf nger zu MULTIPLEX oder einer MULTI PLEX Servicestelle damit die defekte Schmelzsicherung ersetzt werden kann 17 CE KON...

Page 10: ...Empf nger RX 9 12 16 DR pro M LINK Seite 10 Anleitung 2 4 GHz Empf nger RX 9 12 16 DR pro M LINK 985 5320 10 05 12 MIWA Irrtum und nderung vorbehalten MULTIPLEX 20 EINBAUANORDNUNG Max Maximal m gliche...

Page 11: ...RESET and displaying operating status information x HOLD FAIL SAFE function x Integral error counter data logger Voltage and signal errors indicated directly by means of separate LEDs on the receiver...

Page 12: ...nnecting the receiver battery servos speed controllers sensors it is essential to insert the connector the correct way round With other makes of component always check the pin assignment see symbols o...

Page 13: ...transmitter and receiver to Binding mode x Place the transmitter and the receiver aerials close to gether x Switch the transmitter ON in binding mode see the operating instructions supplied with your...

Page 14: ...SAFE settings will cause the model to take up as safe an attitude as possible e g motor idle electric motor OFF control surfaces neutral landing flaps deployed tow release open Selecting the FAIL SAF...

Page 15: ...f transmitting data from the model back to the transmitter When these receivers are employed the telemetric values for receiver battery voltage and connection quality LQI Link Quality Indication are t...

Page 16: ...rically conductive parts e g pushrods x Keep to the recommended installed arrangements 20 sketches A D x High current cables e g those attached to the speed con troller motor and flight battery should...

Page 17: ...d MULTIPLEX Service Centre for replacement of the fuse 17 CE CONFORMITY DECLARATION This device has been assessed and approved in accordance with European harmonised directives This means that you pos...

Page 18: ...6 DR pro M LINK 2 4 GHz receivers Page 18 Instructions for RX 9 12 16 DR pro M LINK 2 4 GHz receivers 985 5320 10 05 12 MIWA Errors and omissions excepted MULTIPLEX 20 RECOMMENDED INSTALLATIONS Max As...

Page 19: ...rsity 8 5070 x Amplification suppl mentaire du signal Pour obtenir une plus grande sensibilit et de ce fait une qualit irr prochable de r ception pour un maximum de port du syst me x Touches SET et LE...

Page 20: ...du nombre de contacts Branchement d un c ble pour PC Diversity ou MULTImate S Branchement pour un module capteur externe Deux sont disponibles pour la r alisation d une chaine de capteurs de mesure su...

Page 21: ...amment de distance de s curit Le processus de Binding est n cessaire dans les cas suivants x A la premi re mise en route du r cepteur 9 3 1 x Apr s un RESET du r cepteur 9 6 x Apr s avoir modifi les r...

Page 22: ...MULTIPLEX ou une des stations services MULTIPLEX 9 5 HOLD et FAIL SAFE Si le r cepteur n a pas de r ception ou reconna t des donn es erron es celui ci utilise les derni res bonnes instructions et les...

Page 23: ...cu vide ou d fectueux section de c ble trop petit etc Le compteur prend en compte les passages de tension en dessous de la barre des 4 5 V peut tre modifi avec le MULTImate ou le RX DataManager 12 2 E...

Page 24: ...ware 13 INDICATIONS DE MONTAGE x Prot gez votre r cepteur contre les vibrations surtout pour une motorisation thermique par ex mousse l g re x Eloignez le r cepteur d au moins 150 mm du moteur lec tri...

Page 25: ...r gulateur gyroscope au travers d UNE seule sortie pour servo Cela peut amener une surcharge au niveau de cette sortie et donc du fusible correspondant La combustion du fusible aurait comme con s quen...

Page 26: ...iel Ne sont pas couvert par la garantie sont des d fauts ou mauvais fonctionnement caus s par x Utilisation non conforme x Absence mauvaise ou aucune r paration effectu e par une station agr e x Mauva...

Page 27: ...le Alta sensibilit e qualit di ricezione per la massima portata x Tasto SET e LED integrati Per Binding impostazione FAIL SAFE RESET e indicazione di stato x Funzioni HOLD FAIL SAFE x Contatore errori...

Page 28: ...zione in nessun caso collegare a queste prese un pacco batteria ricevente 16 BATT Per collegare un cavo con interruttore oppure un pacco batteria RX con connettore alta tensione MULTIPLEX M6 In fase d...

Page 29: ...nza da usare Per informazioni pi detta gliate consulta le istruzioni d uso allegate alla radio M LINK o al modulo HF M LINK gamma di frequenza limitata Modalit Francia x Se la ricevente viene usata co...

Page 30: ...ricevente a quelle di fabbrica RESET 9 6 Dopo il RESET necessario ripetere il Binding 9 3 Nota attivare sempre il FAIL SAFE Per motivi di sicurezza si consiglia di attivare sempre il FAIL SAFE Control...

Page 31: ...di telemetria della riceventi 2 4 GHz RX 9 12 16 DR pro M LINK permette l invio di dati dal modello alla radio Con l impiego di queste riceventi i valori di telemetria Tensione pacco batteria Rx e Qu...

Page 32: ...eriale con duttore p es rinvii x Installare come previsto 20 Figure A D x Accorciare il pi possibile i cavi che sono sottoposti a correnti elevate come p es quelli del regolatore del motore o del pacc...

Page 33: ...questo dovuto all intervento dell elemento termico in seguito ad un sovraccarico Sottoporre il servo ad un controllo accurato prima di un nuovo impiego Inviare la ricevente alla MULTIPLEX o ad un cent...

Page 34: ...9 12 16 DR pro M LINK Pagina 34 Istruzioni per l uso Riceventi 2 4 GHz RX 9 12 16 DR pro M LINK 985 5320 10 05 12 MIWA Con riserva di errori e modifiche MULTIPLEX 20 POSIZIONE DEI COMPONENTI Max massi...

Page 35: ...lificaci n de se al adicional Para mayor sensibilidad y con ello la mejor calidad de recepci n con el mayor alcance posible x Tecla SET y LED integrados Para la asociaci n binding programaci n FAIL SA...

Page 36: ...Nunca conecte una bater a de receptor a estos conectores 16 BATT Conexi n de un cable interruptor o una bater a de receptor con conectores MULTIPLEX M6 Al conectar bater as de receptor servos regulad...

Page 37: ...M LINK o del m dulo RF M LINK x Tras ser modificado el ajuste de la emisora del rango de frecuencias Encontrar notas sobre ello en el manual de instrucciones de su emisora o del m dulo RF M LINK Modo...

Page 38: ...activa utilizando la tecla SET del receptor u opcionalmente utilizando algunas emisoras v a radio Si desea desactivar de nuevo el FAIL SAFE tendr que reiniciar el receptor a los valores de f brica RES...

Page 39: ...compatibles con telemetr a RX 9 12 16 DR pro M LINK ofrecen la posibilidad de enviar datos desde el modelo a la emisora Al utilizar este tipo de receptores los valores telem tricos voltaje de la bater...

Page 40: ...taci n como P ej los de re guladores motor y bater as tan cortos como pueda x Use el filtro de picos PeakFilter 8 5180 al utilizar sistemas de doble alimentaci n diodos x Puede optimizar la calidad de...

Page 41: ...sin dilaci n Env e el receptor a MULTIPLEX o a un servicio t cnico MULTI PLEX para que el fusible defectuoso pueda ser reemplazado 17 DECLARACI N DE CONFORMIDAD CE El dispositivo ha sido probado seg...

Page 42: ...RX 9 12 16 DR pro M LINK P gina 42 Manual de instrucciones de los receptores 2 4 GHz RX 9 12 16 DR pro M LINK 985 5320 10 05 12 MIWA Salvo error correci n o modificaci n t cnica MULTIPLEX 20 MONTAJE...

Reviews: