background image

              Operating Instructions for M-LINK sensors 

MULTIPLEX Modellsport GmbH & Co.KG  •  Westliche Gewerbestraße 1  •  D-75015 Bretten (Gölshausen)  •  www.multiplex-rc.de 

Page 2/2

         

Ins

tr

uc

tions

 -

 M-

LIN

K

 s

ens

or

s • # 82 

5494 (

10-

0

4

-23/B

R

A

N

)  •  

E

rr

o

rs

 and omi

s

si

ons

 ex

cepted!  •  

¤

 MU

LT

IP

LE

X

 

x

Magnetic rev-count sensor (# 8 5415)

Attach the magnet (# 89 3401) to a suitable point on the rotating component, ideally 
glued in a suitable hole, flush with the surface. Connect the rev-count pick-up to the 
sensor case, taking care to keep the connector the right way round, as indicated by 
the colours printed on the cable. 
The distance between the rev-count pick-up (# 89 3400) and the magnet should not 
exceed 1 mm. 

!

 Take care to avoid throwing the rotating component out of balance. Even though 

one magnet weights only 0.02 g, you may need to attach a second magnet on the 
opposite side to the first one to avoid imbalance. 

!

 Take care to avoid weakening the rotating component. If you can install the 

magnet before the component is balanced, locate it exactly opposite the point where 
material has to be removed to obtain proper balance. 
For high rotational speeds, and when using components which are already balanced, 
it is advisable to attach two magnets directly opposite each other, so that correct 
balance is maintained. The default number of magnets is one, but this can be altered 
using the MULTImate or Sensor DataManager (in which case a maximum of eight 
magnets can be used). 

Features which can be activated or adjusted using MULTImate or Sensor DataManager:

Address 

Address (transmitter screen line) at which the rev-count is displayed 

Top alarm 

Upper rpm value, above which an alarm is triggered 

Bottom alarm 

Lower rpm value, below which an alarm is triggered 

Option 

Additional output of minimum, average or maximum rotational speed 

Option address 

Address (screen line) at which the option value is displayed 

Blade count 

Number of magnets 

x

Vario / altitude sensor (# 8 5416)

The vario / altitude sensor must be installed in the model in a location where it can 
monitor atmospheric pressure without interference. In this case ‘interference’ means 
any airflow which passes through the model. When initialised, the vario / altitude 
sensor automatically sets a starting altitude of 0 m, i.e. it always generates an 
altitude of 0 m when activated. The audible output of sink and climb in vario mode 
can be switched ON and OFF at the transmitter if you assign a switch to this function 
in the transmitter control menu (Setup -> Assignment list -> Switch -> Trainer/Vario). 
The audible signals for climb and sink alter in frequency with increasing rates of 
climb and descent. 

Features which can be activated or adjusted using MULTImate or Sensor DataManager:

Address 

Address (transmitter screen line) at which the climb rate is displayed 

Top alarm 

Upper climb rate value, above which an alarm is triggered 

Bottom alarm 

Lower climb rate value, below which an alarm is triggered 

Option 

Additional output of minimum and maximum climb rate 

Option address 

Address (screen line) at which the option value is displayed 

Integration 

Integration period – time interval over which the changes in altitude are 
integrated (period until the new altitude value is calculated) 

... 

As above, but for altimeter (without integration period) 

4. S

PECIFICATION

Sensor type 

Voltage 

Current 35 A 

Current 100 A 

Temperature 

Order No. 

# 8 5400 

# 8 5403 

# 8 5401 

# 8 5402 

Measuring range 

+/-60 V 

35 A / 16 Ah 

100 A / 16 Ah 

-25... +700°C

(1*)

Resolution 

0.1 V 

0.1 A / 1 mA/h

/ 1% 

0.1 A / 1 mA/h 

/ 1% 

0.1°C 

Screen line / 
address 

2 (U

1

)

 (2*)

 3 

(2*)

 3 

(2*)

 4 

(T

1

)

 (2*)

Temp. range 

-25 ... +60°C 

Current drain 

3 mA 

Case dimensions  

31 x 20 x 7 mm 

42 x 32 x 7 mm 

31 x 26 x 7 mm 

31 x 20 x 7 mm 

Weight 

approx. 10 g 

approx. 12 g 

approx. 10 g 

approx. 10 g 

Voltage range 

3.5 V – 9.0 V 

Special feature 

2

nd

 measuring 

channel can be 

activated 

MPX M6 

connector 

Excl. MPX M6 

connector 

2

nd

 measuring 

channel can be 

activated 

Sensor type 

RPM - optical 

RPM - magnetic 

Vario - Altimeter 

Order No. 

# 8 5414 

# 8 5415 

# 8 5416 

Measuring range 

400 ... 50,000 rpm 

(max. 3 blades) 

100 ... 50,000 rpm 

(max. 3 blades) 

+/- 50 m/s (vario) / 

-500 ... +2000 m 

(altimeter) 

Resolution 

100 rpm 

100 rpm 

0.1 m/s / 1 m 

Screen line / 
address 

5

(2*)

 5 

(2*)

 

6 / 7 

(2*)

Temp. range 

-25 ... +60°C 

Current drain 

3 mA 

8 mA 

Case dimensions 

31 x 20 x 7 mm 

31 x 20 x 9 mm 

Weight 

approx. 10 g 

approx. 10 g 

approx. 10 g 

Voltage range 

3.5 V – 9.0 V 

Special feature 

Blade count variable 

using jumper (2 - 4) / 

MULTImate or SDM 

(1 - 8) 

Magnet count variable 

using MULTImate or 

SDM (1 - 8) 

 

 

 

 

(1*)  According to the temperature pick-up in use 

(2*)  Factory / default setting, currently only with ROYALpro (

SW 3.XX

)

5. G

UARANTEE

/ L

IABILITY 

E

XCLUSION

The company MULTIPLEX Modellsport GmbH & Co.KG accepts no liability of any 
kind for loss, damage or costs which are due to the incorrect use and operation of 
this product, or which are connected with such operation in any way. Unless the law 
expressly states otherwise, the liability on the part of MULTIPLEX Modellsport GmbH 
& Co.KG to pay damages, regardless of the legal argument employed, is limited to 
the invoice value of those products supplied by MULTIPLEX Modellsport GmbH & 
Co.KG which were directly involved in the event in which the damage occurred. This 
does not apply if liability is incurred according to statutory law on account of 
intentional or gross negligence. 
We guarantee our products in accordance with the currently valid statutory 
regulations. If you wish to make a claim under guarantee, your initial course of action 
should always be to contact the dealer from whom you purchased the equipment. 
The guarantee does not cover faults and malfunctions which are caused by the 
following: 

x

  Incorrect or incompetent use 

x

  Maintenance carried out incorrectly, belatedly or not at all,  

or not carried out by an authorised Service Centre 

x

 Incorrect connections 

x

  The use of accessories other than genuine MULTIPLEX items 

x

  Modifications or repairs which were not carried out by MULTIPLEX or by an 

authorised MULTIPLEX Service Centre 

x

  Accidental or intentional damage 

x

  Defects due to normal wear and tear 

x

  Operation of the unit outside the limits stated in the specification

x

  Operation of the unit in conjunction with equipment made by other manufacturers. 

6. CE C

ONFORMITY 

D

ECLARATION

This device has been assessed and approved in accordance with 
European harmonised directives. 
This means that you possess a product whose design and construction 
fulfil the protective aims of the European Community designed to ensure the safe 
operation of equipment. 
The detailed CE conformity declaration can be downloaded in the form of a PDF file 
from the Internet under www.multiplex-rc.de. It is located in the DOWNLOADS area 
under PRODUKTINFOS. 

7.  D

ISPOSAL 

N

OTES 

Electrical equipment marked with the cancelled waste bin symbol must 
not be discarded in the standard household waste; instead it should be 
taken to a suitable specialist disposal system. 
In the countries of the EU (European Union) electrical equipment must 
not be discarded via the normal domestic refuse system (WEEE - Waste 
of Electrical and Electronic Equipment, Directive 2002/96/EG). You can 
take unwanted equipment to your nearest local authority waste collection 
point or recycling centre. There the equipment will be disposed of correctly and at no 
cost to you. 
By returning your unwanted equipment you can make an important contribution to 
the protection of the environment! 

Summary of Contents for 4041033074046

Page 1: ...hierbei auf eine sichere Befestigung vor allem bei den in der N he von rotierenden Teilen angebrachten Komponenten Der Temperaturf hler sollte m glichst fl chig an der Messstelle befestigt sein Mit d...

Page 2: ...resse 2 U1 2 3 2 3 2 4 T1 2 Einsatzbereich 25 60 C Stromverbrauch 3 mA Ma e Geh use 31 x 20 x 7 mm 42 x 32 x 7 mm 31 x 26 x 7 mm 31 x 20 x 7 mm Gewicht ca 10 g ca 12 g ca 10 g ca 10 g Spannungsbereich...

Page 3: ...e temperature pick up and the sensor case at a suitable location in the model ensuring that they are securely mounted this applies in particular to components which are located in the vicinity of rota...

Page 4: ...e dimensions 31 x 20 x 7 mm 42 x 32 x 7 mm 31 x 26 x 7 mm 31 x 20 x 7 mm Weight approx 10 g approx 12 g approx 10 g approx 10 g Voltage range 3 5 V 9 0 V Special feature 2 nd measuring channel can be...

Page 5: ...ible la sonde de temp rature doit tre fix e de telle mani re ce qu elle ait le plus de surface possible en contact avec le point de mesure Avec cette sonde de temp rature vous pouvez mesurer des temp...

Page 6: ...2 3 2 4 T1 2 Dom d utilisation 25 60 C Consommation 3 mA Dimensions boitier 31 x 20 x 7 mm 42 x 32 x 7 mm 31 x 26 x 7 mm 31 x 20 x 7 mm Poids env 10 g env 12 g env 10 g env 10 g Domaine de tension 3 5...

Page 7: ...onentes colocados cerca de piezas en movimiento La sonda de temperatura debe fijarse lo m s plana posible al punto de medici n Con esta sonda de temperatura pueden medirse temperaturas de hasta 200 C...

Page 8: ...3 2 3 2 4 T1 2 mbito de Utilizaci n 25 60 C Consumo 3 mA Dimensiones carcasa 31 x 20 x 7 mm 42 x 32 x 7 mm 31 x 26 x 7 mm 31 x 20 x 7 mm Peso aprox 10 gr aprox 12 gr aprox 10 gr aprox 10 gr Voltaje op...

Page 9: ...are la sonda termica 8 5412 allegata al sensore della temperatura T1 Fissare quindi il sensore della temperatura e il corpo del sensore nel punto adatto del modello e fare attenzione ad un fissaggio s...

Page 10: ...upplementare di velocit ascensionale minima e massima Opzione indirizzo Indirizzo riga display su trasmettitore sul quale visualizzare un valore opzionale Integrazione Tempo di integrazione intervallo...

Page 11: ...Anleitung Sensoren M LINK 82 5494 10 04 23 BRAN Irrtum und nderung vorbehalten MULTIPLEX 1 BATT ESC 3 V Sensor U1 U2 2a BATT BATT SAFETY SWITCH TwinBatt RX Batt Sensor BATT A Sensor 100 Switch RX BATT...

Reviews: