84
MultiModemISI Hybrid Series, ISIHI-2S
Chapter 4—MODEM AT Commands, S-Registers, Result Codes
Modem
S3
Return Character
Unit: Decimal
Range: 0–127
Default: 13 (^M)
S3 defines the carriage return character by its decimal ASCII code. The default setting is
the ^M character (decimal 13), which is the code for E
NTER
on most keyboards. S3 may
be set for any ASCII character.
Note: If you change the S3 value, you must make corresponding changes in your data
communications software.
S4
Line Feed Character
Unit: Decimal
Range: 0–127
Default: 10 (^J)
S4 defines the line feed character by its decimal ASCII code. The default setting is ^J
(decimal 10), which is the code for the line feed key on most keyboards that have such a
key. S4
may be set for any ASCII character.
S5
Backspace Character
Unit: Decimal
Range: 0–127
Default: 8 (^H)
S5 defines the backspace character by its decimal ASCII code. The default setting is the
^H character (decimal 8), which is the code for B
ACKSPACE
on most keyboards. S5
may be
set for any ASCII character. Setting S2 to a value greater than 32 disables the backspace
character.
Note: If you change the S5 value, you must make corresponding changes in your data
communications software.
S6
Wait Time for Dial Tone
Unit: 1 second
Range: 2–65 (North America), 4–255 (International), 4–7 (U.K.)
Default: 2 (North America), 4 (International and U.K.)
S6 defines the length of time the modem waits after E
NTER
is pressed before executing a
dial command. The default setting is two seconds for North America, four seconds
elsewhere.
S7
Time to Wait for Carrier
Unit: 1 second
Range: 1–255 (USA), 1–45 (Canada and International), or 1–55 (U.K.)
Default: 50 (North America and International) or 55 (U.K.)
S7 determines amount of time the modem waits for a carrier signal before it disconnects.
The default value is 50 seconds except the UK model, which defaults to 55 seconds. This
means that after dialing the modem waits for a carrier signal for up to 50 or 55 seconds
and if none is detected terminates the call. The maximum S7
value is 255 seconds for
the US model, 45 seconds for Canadian and International models, and 55 seconds for
the UK model. S7 also determines the wait for silence time for the @ dial modifier.
Summary of Contents for MultiModem ISIHI-2S
Page 1: ...MultiModemISI Hybrid Series Model ISIHI 2S 88301150 Copyright 1998 by Multi Tech Systems Inc...
Page 5: ...MultiModemISI Hybrid Series ISIHI 2S 5 Introduction 1...
Page 15: ...MultiModemISI Hybrid Series ISIHI 2S 15 Hardware Installation 2...
Page 20: ...20 MultiModemISI Hybrid Series ISIHI 2S Hardware Installation...
Page 21: ...MultiModemISI Hybrid Series ISIHI 2S 21 Software Driver Installation 3...
Page 62: ...62 MultiModemISI Hybrid Series ISIHI 2S Chapter 3 Software Driver Installation...
Page 63: ...MultiModemISI Hybrid Series ISIHI 2S 63 MODEM AT Commands S Registers and Result Codes 4...
Page 111: ...MultiModemISI Hybrid Series ISIHI 2S 111 Troubleshooting 6...
Page 116: ...116 MultiModemISI Hybrid Series ISIHI 2S Chapter 6 Troubleshooting Guide...
Page 117: ...MultiModemISI Hybrid Series ISIHI 2S 117 Service Warranty and Technical BBS 7...
Page 122: ...122 MultiModemISI Hybrid Series ISIHI 2S Chapter 7 Service Warranty and Technical BBS...
Page 123: ...MultiModemISI Hybrid Series ISIHI 2S 123 Appendix...
Page 169: ...MultiModemISI Hybrid Series ISIHI 2S 169 Glossary...
Page 181: ...MultiModemISI Hybrid Series ISIHI 2S 181 Index...
Page 186: ...186 MultiModem ISI Hybrid Series ISIHI 2S Glossary...