C O N F I G U R AT I O N
3 5
M U LT E N E T P O C K E T P A D
with ATMs.
Note:
If Flow Control is set to
None
, a simple 3-wire Crossed Serial cable can be used
instead of a Full Crossed Serial cable. See the Appendix for wiring info.
Once you have the Serial Interface setup, configure the Network Applications to provide the
gateway between serial and Ethernet communication.
Save/Reboot the PocketPAD once you have finished making changes.
Note:
Make sure your Connection Type is set to the configuration on the dip switches.
Application Type
The following options are available when you [
Change
] or [
Add
] Application Types.
TCP Application Type
Use TCP/IP to transmit packets over the Ethernet network.
TCP Application Parameters overview:
Application Name -
This is the label you entered at the time of adding the Application.
Serial Interface
-
Indicates the Serial Port to which these changes will impact.
Connection Type -
Default is Passive.
Passive
- Application accepts incoming TCP socket connections
from remote hosts.
Set ‘
Remote Host / IP Address
’ & ‘
Remote TCP Port
’
to accept connections from that specific Host:Port.