background image

Copyright Müller-Elektronik GmbH u. Co.       UNI-Control S Installation and User´s Guide  (01/95)      Seite - 31 -

                       |  \------------------\-----+
                       |
                       v
                       |
                Enter kilograms
                       |
                       v   /-----------------/-----+
+-------------------------/-----------------/      |                 Left:
| C a l i b r a t i o n   |                 |  T1  |                 After the bin has been filled the
|-------------------------|-----------------|------|                 spreader is shut off. The weight is
| I m p u l s e / k g     |                 |  T2  |                 determined and entered via the
decimal
|-------------------------|-----------------|------|                 keyboard.
|       3 1 5 0   I m p . |                 |  T3  |
|-------------------------|-----------------|------|
|         1 2 , 5 0   k g |                 |  T4  |
+-------------------------\-----------------\      |
                       |   \-----------------\-----+
                       |
                       |
          After pressing the  "input" key
                       |
                       |
                       v   /-----------------/-----+
+-------------------------/-----------------/      |                 Left:
|   M a c h i n e         |          M e nu |  T1  |---> Ms          After pressing the  "Input" key
|-------------------------|-----------------|------|                 the computer calculates and displays
the
| I m p u l s e s/ k g    |                 |  T2  |                 impulses/kg rate. The operation
process
|-------------------------|-----------------|------|                 can now be started. The spread rate
can
|                         |                 |  T3  |                 be adjusted via the + / - keys 10%
|-------------------------|-----------------|------|                 degrees in relation to the pre-set
rate.
|       2 6 2 , 5 0       |         N e x t |  T4  |--------+
+-------------------------\-----------------\      |        |
                           \-----------------\-----+        |        Right:
                                                            |        Press the T1 key for the menu
selection.
                                                            |
                                                            v

Data block OPERATION

                                                            |
                       +------------------------------------+---(Op)
                       |
                       v   /-----------------/-----+                 Left:
+-------------------------/-----------------/      |                 Here interesting data concerning the
|       6 , 8 k m / h     |         M e n u |  T1  |---> Ms          operation process is displayed:
|-------------------------|-----------------|------|                 speed, current application rate,
|                         | T e r m i n a t |  T2  |--->             adjusted deviation from the pre-set
|-------------------------|-----------------|------|                 rate, the remaining working width,
where
|     3 2 0   k g / h a   |           B i n |  T3  |--->             one or several boom sections have
been
|-------------------------|-----------------|------|                 closed.
| + 1 0 %   6 , 0   m     |         N e x t |  T4  |---+
+-------------------------\-----------------\      |   |             Right:
                           \-----------------\-----+   |             Press the T2 key to save the recorded
                                                       |             data
                                                       |             Press the T1 key for the order data
                                                       |             Press the T3 key for the bin capacity
                                                       |             display as in the field sprayer
program
                                                       |             Press the T4 key to proceed to the
next
                                                       |             display.
                       +-------------------------------+
                       |
                       |
                       v   /-----------------/-----+
+-------------------------/-----------------/      |                 Left:
|   5 1 , 5   k g / m i n |         M e n u |  T1  |---> Ms          Displays the current spread rate in
|-------------------------|-----------------|------|                 kg/min
|                         |                 |  T2  |
|-------------------------|-----------------|------|                 Right:
|                         |                 |  T3  |                 Press the T1 key for the order data
|-------------------------|-----------------|------|                 Press the T4 key to proceed to the
next
|                         |         N e x t |  T4  |---> Ms          display.
+-------------------------\-----------------\      |
                           \-----------------\-----+

www.ROLTRONIK.pl

Summary of Contents for 302531

Page 1: ...Datei 302531 02_E ME011513 DOC Installation and User s Guide UNI Control S January 1995 w w w R O L T R O N I K p l...

Page 2: ...chine adapter 10 2 2 3 Sensor X Establishing the distance 20 10 2 2 4 Sensor Y Working position 11 2 3 Tractor signal distributor for tractors with a signal socket 12 2 4 Connecting machines 12 2 4 1...

Page 3: ...Copyright M ller Elektronik GmbH u Co UNI Control S Installation and User s Guide 01 95 Seite 3 w w w R O L T R O N I K p l...

Page 4: ...nsole art no 312227 Mounted to the tractor cabin Includes the bracket with profile slide and battery connection fo the switch box or the machine adapter 15 Battery connection cable art no 312155 for t...

Page 5: ...on the switch box s or machine adapter s 48 pin machine plug 4 When the device is switched on the program and the connected machine s individual data are called up automatically The UNI Control S can...

Page 6: ...area being treated total area the quantity sprayed as well as the total quantity working time and the distance travelled are recorded continually With the installation of an electronic pressure sensor...

Page 7: ...nism of the sowing disc drive slip clutch locking pin the Reed contact sensors carry out a control during standstill In the case of a defect standstill an alarm signal is set off Up to 12 aggregates c...

Page 8: ...however instead of the grain loss display the rpm of the main shaft is continually displayed 1 3 7 Universal Telescope spreader The UNI Control S can control the spray rate from sludge spreaders with...

Page 9: ...distributor 16 The sensor X 20 cardan shaft wheel is supplied as standard The sensor Y 18 working position the power take off shaft rotation sensor 19 and the radar device 21 can easily be retro fitte...

Page 10: ...n to the free end of the adapter Fitting to a 4 wheel drive tractor and to a MB Trac Mount hose clamp with the magnet to the cardan shaft The sensor should point towards the magnets from a distance of...

Page 11: ...et is mounted with the V4A bolt supplied to a part of the machine which changes its position from transport to working position The sensor is then fixed to a static part of the tractor opposite to the...

Page 12: ...interrupted in the tractor distributor Fitting is carried out as described in paragraph 2 2 2 2 4 Connecting machines Machines trailed or mounted to the tractor as well as a self propelled machine e...

Page 13: ...user Specified implementation also includes adhering to the operation and maintenance conditions stipulated by the manufacturer The relevant accident prevention regulations as well as other recognize...

Page 14: ...first letter on the key is displayed the second time the key is pressed the second letter on the key is displayed and the third time the key is pressed the number is displayed Wait two seconds before...

Page 15: ...Copyright M ller Elektronik GmbH u Co UNI Control S Installation and User s Guide 01 95 Seite 15 3 2 Operating scheme w w w R O L T R O N I K p l...

Page 16: ...rate comments and the number of the machine With the exception of the pre set rate this data together with the data recorded such as worked area working time etc is stored when the ordering process i...

Page 17: ...witch box or machine plug with the UNI Control making sure that it is set in off position Switch on the UNI Control S the machine adapter identifies the machine automatically and the corresponding pro...

Page 18: ...hine 1 0 0 F r a n c a i s T2 connected S p r a y e r E n g l i s h T3 Right Choice of the language required i n s t a l l e d D e u t s c h T4 only once Order has started Working position On Op Order...

Page 19: ...next display v Left Any text can be entered using the O r d e r M e n u T1 Ms alphabetical keys It will be stored as comment C o m m e n t S t a r t T2 Op Right L I G H T R A I N T3 Press the T1 key f...

Page 20: ...rocess for Impulses 100m v v Right C a l i b r a t i o n B a c k T1 Press the T1 key to interrupt the calibration process D r i v e e x a c t l y 1 0 0 m T2 t h e n s t o p a n d p r e s s T3 The cali...

Page 21: ...e T4 key to proceed to the next display v Description of the calibration process Right C a l i b r a t io n B a c k T1 Press the T1 key to interrupt the calibration process C a l i b r a t e d e l t e...

Page 22: ...nstalled a 1 should be entered here Right Press the T1 key for menu selection Press the T4 key to proceed to the next display v Left M a c h i n e M e n u T1 To calculate the residue in the bin tank e...

Page 23: ...al keyboard If the control is too C o n t r o l T2 slow the figure must be increased In the case of over control i e with a c o n s t a n t T3 pre set rate of 200 l ha the control goes from 160 l ha t...

Page 24: ...C o n t r c h e s t Y e s T2 return flow is being measured via the liquid flow meter e g Holder Rau w b a c k f l o w N o T3 control chest The T3 key confirms that the return flow m e a s u r e m e n...

Page 25: ...th 1 0 1 2 0 m N e x t T4 Right Press the T1 key for menu selection Press the T2 key to confirm the end of the order Press the T3 key for bin tank capacity Press the T4 key for further operation data...

Page 26: ...t the bin s contents do not have to be entered before filling The contents of the bin are displayed on the left hand side of the bottom line in the line above the required amount to be filled The UNI...

Page 27: ...dividual order v Left M e m o r y 5 M e n u T1 Ms Displays the working times Working time machine runs if the 6 7 3 h M a c h T2 machine is in working position Working time tractor runs if 7 5 5 h T r...

Page 28: ...h A L A R M T1 the range entered P r e s s u r e o u t T2 The computer can no longer adjust the pre set application rate within the o f r a n g e T3 valid pressure limit 1 2 b a r T4 The operator has...

Page 29: ...sprayed and the worked area T2 e g within one season 1 0 3 3 7 5 h a D e l e t e T3 Right Press the T1 and T3 keys to delete the N e x t T4 Op figures shown on the left Press the T4 key to go back to...

Page 30: ...is to be determined v Left M a c h i n e M e n u T1 Ms The impulses kg from the last calibration test are displayed If the I m p u l s e k g T2 impulses kg figure is known it can be entered via the de...

Page 31: ...0 N e x t T4 Right Press the T1 key for the menu selection v Data block OPERATION Op v Left Here interesting data concerning the 6 8 k m h M e n u T1 Ms operation process is displayed speed current a...

Page 32: ...o not have to be entered Up to 16 additional shaft speeds in the region of 20 to 10 000 rpm can be monitored via the machine plug The shaft speed input is activated by entering the name via the decima...

Page 33: ...y pressing the key twice because the middle width is equivalent to 1 2 the working width To reset press the T3 key or exit the working position v Left With the T4 key the curent rpm C H O P P E R M e...

Page 34: ...itch box nor a machine plug is connected the 48 pin plug on the computer should always be covered with the protective cap 4 2 Switch box machine plug The switch box and machine plug are also maintenan...

Page 35: ...sor Check sensor The intended spread rate has not been reached The current quantity is below the pre set rate The horn is sounding The setting motor has been wrongly poled The rate is controlled downw...