Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 31 -
| \------------------\-----+
|
v
|
Enter kilograms
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| C a l i b r a t i o n | | T1 | After the bin has been filled the
|-------------------------|-----------------|------| spreader is shut off. The weight is
| I m p u l s e / k g | | T2 | determined and entered via the
decimal
|-------------------------|-----------------|------| keyboard.
| 3 1 5 0 I m p . | | T3 |
|-------------------------|-----------------|------|
| 1 2 , 5 0 k g | | T4 |
+-------------------------\-----------------\ |
| \-----------------\-----+
|
|
After pressing the "input" key
|
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| M a c h i n e | M e nu | T1 |---> Ms After pressing the "Input" key
|-------------------------|-----------------|------| the computer calculates and displays
the
| I m p u l s e s/ k g | | T2 | impulses/kg rate. The operation
process
|-------------------------|-----------------|------| can now be started. The spread rate
can
| | | T3 | be adjusted via the + / - keys 10%
|-------------------------|-----------------|------| degrees in relation to the pre-set
rate.
| 2 6 2 , 5 0 | N e x t | T4 |--------+
+-------------------------\-----------------\ | |
\-----------------\-----+ | Right:
| Press the T1 key for the menu
selection.
|
v
Data block OPERATION
|
+------------------------------------+---(Op)
|
v /-----------------/-----+ Left:
+-------------------------/-----------------/ | Here interesting data concerning the
| 6 , 8 k m / h | M e n u | T1 |---> Ms operation process is displayed:
|-------------------------|-----------------|------| speed, current application rate,
| | T e r m i n a t | T2 |---> adjusted deviation from the pre-set
|-------------------------|-----------------|------| rate, the remaining working width,
where
| 3 2 0 k g / h a | B i n | T3 |---> one or several boom sections have
been
|-------------------------|-----------------|------| closed.
| + 1 0 % 6 , 0 m | N e x t | T4 |---+
+-------------------------\-----------------\ | | Right:
\-----------------\-----+ | Press the T2 key to save the recorded
| data
| Press the T1 key for the order data
| Press the T3 key for the bin capacity
| display as in the field sprayer
program
| Press the T4 key to proceed to the
next
| display.
+-------------------------------+
|
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| 5 1 , 5 k g / m i n | M e n u | T1 |---> Ms Displays the current spread rate in
|-------------------------|-----------------|------| kg/min
| | | T2 |
|-------------------------|-----------------|------| Right:
| | | T3 | Press the T1 key for the order data
|-------------------------|-----------------|------| Press the T4 key to proceed to the
next
| | N e x t | T4 |---> Ms display.
+-------------------------\-----------------\ |
\-----------------\-----+
www.ROLTRONIK.pl