Copyright Müller-Elektronik GmbH u. Co. UNI-Control S Installation and User´s Guide (01/95) Seite - 23 -
| 6 | N e x t | T4 |---+ Press the T1 key for menu selection.
+-------------------------\-----------------\ | | Press the T4 key to proceed to the
next
\-----------------\-----+ | display
|
v
v
+-------------------------------+
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| M a c h i n e | M e n u | T1 |---> Ms A maximum of 12 boom sections are
|-------------------------|-----------------|------| allowed for.
| N o. o f n o z z l . | | T2 | If e.g. 4 boom sections exist, the
|-------------------------|-----------------|------| 5th boom section is set to 0 via the
| P a r t w i d t h 5 | | T3 | decimal keyboard.
|-------------------------|-----------------|------|
| 0 | N e x t | T4 |---+ Right:
+-------------------------\-----------------\ | | Press the T1 key for menu selection.
\-----------------\-----+ | Press the T4 key to proceed to the
next
| display.
+-------------------------------+
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| M a c h i n e | M e n u | T1 |---> Ms To confirm the entered values the
|-------------------------|-----------------|------| whole no of nozzles is shown here.
| N o. o f n o z z l . | | T2 |
|-------------------------|-----------------|------|
| | | T3 | Right:
|-------------------------|-----------------|------| Press the T1 key for menu selection.
| 1 2 | N e x t | T4 |---+ Press the T4 key to proceed to the
next
+-------------------------\-----------------\ | | display.
\-----------------\-----+ |
|
+-------------------------------+
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| M a c h i n e | M e n u | T1 |---> Ms Enter the control constant via the
|-------------------------|-----------------|------| decimal keyboard. If the control is
too
| C o n t r o l | | T2 | slow the figure must be increased. In
|-------------------------|-----------------|------| the case of over-control, i.e. with a
| c o n s t a n t : | | T3 | pre-set rate of 200 l/ha the control
|-------------------------|-----------------|------| goes from 160 l/ha to 230 l/ha and
then
| 1 , 5 0 | N e x t | T4 |---+ to 180 l/ha etc.then the control
+-------------------------\-----------------\ | | constant is too high.The value
entered
\-----------------\-----+ | must be reduced Depending on the
field
| sprayer used, figures of 0.5 to 10
are
| feasible.
|
| Right:
| Press the T1 key for menu selection.
| Press the T4 key to proceed to the
next
v display.
+-------------------------------+
|
v /-----------------/-----+
+-------------------------/-----------------/ | Left:
| M a c h i n e | M e n u | T1 |---> Ms Description of the control chest
|-------------------------|-----------------|------|
|C o n t r . c h e s t | - > Y e s | T2 |---------+ Right:
|-------------------------|-----------------|------| | Select the control chest
| w i t h c o n s t . | N o | T3 |---> Ms | The T2 key confirms that a control
|-------------------------|-----------------|------| | chest with equal pressure is
connected
| p r e s s u r e ? | N e x t | T4 |---> Ms | The T3 key confirms that it is a
control
+-------------------------\-----------------\ | | chest without equal pressure control
\-----------------\-----+ | (Müller-Elektronik control chest).
The
| arrow shows the type of control chest
| selected
| Press the T1 key for menu selection.
| Press the T4 key to proceed to the
next
| display
|
|
|
+-------------------------------------+
|