Paul Mueller Company Serving Beer Tank
Effective April 25, 2018
Owner’s Manual, Part No. 9865302
28
6.1 TROUBLESHOOTING CHART
Section 6.0 – Troubleshooting
Description
Reason
Cause
Solution
The serving
beer tank does
not pressurize
or loses
pressure.
Manway is not sealed.
Gasket broken.
Replace gasket.
Hand wheel is not tightened.
Inspect the position of the clamping
bar and tighten the hand wheel.
Piercing unit.
Coupling nut is not tightened.
Adjust with spanner wrench.
Pressure safety valve.
Outlet valve is not closed.
Close outlet valve.
Sight glass is leaking.
Gasket is broken.
Replace gasket.
Pressure drops too fast.
Pressure safety valve is broken.
Replace pressure safety valve.
Pressure safety valve is incorrectly set.
Adjust to correct pressure.
Refrigeration
is not running.
No refrigerant supply.
Valves are still closed.
Open valves.
Pump is not running.
Turn on pump.
Beer leaking at
piercing valve.
Piercing valve not well connected.
Gasket is broken.
Replace gasket.
Inliner not well connected.
Inliner outlet is damaged.
Replace inliner.