Paul Mueller Company Serving Beer Tank
Effective April 25, 2018
Owner’s Manual, Part No. 9865302
4
2.3 INSTRUCTIONS FOR GENERAL USE (CONTINUED)
12. All local, state, and national regulations valid at the place of assembly regarding industrial safety are to
be observed.
13. Local, state, and national regulations regarding safe operation of pressure vessels are to be observed.
TABLE 1: OPERATIONAL DATA
Description
Tank
Cooling
Contents
See data plate
See data plate
Maximum admissible contents
See data plate
See data plate
Maximum/minimum admissible operating pressure
2/0 bar (30/0 psi)
—
Operating pressure
—
3 bar (43 psi)
Maximum/minimum admissible operating temperature
50/0ºC (122/32ºF)
50/0ºC (122/32ºF)
Medium
Beer/Gas
Cooling water
Test pressure at a temperature of 10 to 30ºC (50 to 86ºF)
2.7 bar (39 psi)
4.3 bar (62 psi)