12
4.3 INSTALLATION PRECAUTIONS
CAUTION: Because hoisting the serving beer tank is necessary during installation, please observe
all required safety precautions.
IMPORTANT: During hoisting, make sure no foreign (i.e., not rust proof) metals come in contact
with the serving beer tank as this could lead to undesired corrosion. Wood or plastic support
material is recommended, as well as the use of clean slings.
Before placing the serving beer tanks, inspect the location’s floor to determine whether it provides
adequate support. Take point load into consideration.
In the event that the tanks will be located in an environment that poses potential risk (i.e., in a
situation where there is the likelihood of vibrations caused by heavy traffic, earthquakes, or due to
installation on a movable platform, such as a ship), consultation with your Paul Mueller Company
representative to discuss these conditions is required. Extra stability measures should be taken
before placement of the serving beer tank in these instances.
CAUTION: Various supplies are required for the beer tank: a cool water source, a compressor,
beer mains, and beer hoses take up space around the serving beer tank and can result in less space
for service and waiting. Ensure these supplies do not place an undesired reaction force on tanks,
appendages, and frames, as this can lead to installation instability.
IMPORTANT: Ensure the tank is placed in a frost-free location without exposure to direct sunlight
with a constant temperature between 0–30°C (32–86°F).
Make sure the site is properly equipped with all necessary equipment and supplies before proceeding with
installation. The services of a plumber and/or an electrician may be needed before installing the water
cooling system.
Serving beer tanks should only be lifted by a forklift while in frame. If not in frame, serving beer tanks
should be lifted by no less than two (2) people. Paul Mueller Company suggests using lashing gear to lift the
tanks when not using a forklift. It is recommended to lift the tanks from both ends, using the manway and
center end point (using a threaded bolt in the tank) to lift from center end point.
WARNING: Under no circumstances should the tanks be lifted while pressurized.
!
!
!