  TABLE 3: OTHER TECHNICAL DATA

 

  TABLE 4: WEIGHTS AND DIMENSIONS

Description

Specification 

Material, tank

1.4301 (AISI 304)

Material, outside housing

1.4301 (AISI 304)

Wall thickness, cylinder

2mm (0.0787")

Wall thickness, bottom

2.1mm (0.0826")

Wall thickness, outside housing (by isolated tanks)

1.2mm (0.0472")

Connection dimensions, piercing valve

DN40 (Approximately 1

1

2

")

Connection dimensions, distributor

5

8

"

Material / diameter, cooling water pipe

Copper / 

1

2

"

Length, cooling water pipe / hl tank contents

3 m/hl

Contact surface, cooling pipe

0.09 m2/hl

Dimensions, cooling water connection

2 x G 

5

8

" of G 

3

4

" outer thread

Cooling water, temperature

Approximately 2.5°C (36.5ºF)

Cooling water, delivery

Approximately 250 liter/hour

Cooling time, 10ºC > 5ºC (50ºF > 41ºF)

20 hours

Resistance, cooling spiral

3.6–5.0 psi

Dimensions, manway

420mm x 320mm (15.5" x 12.5")

Type of  

Serving Beer Tank

Contents

liter

Vessel Diameter

Inner/Outer

mm

Capacity

liter

Length

mm

Weight

kg (lbs) 

Weight

on Pallet

 kg (lbs)

Double-wall 

1,500

791/860

1,500

3,360

295 (651)

315 (695)

Single-wall  

1,500

791

1,500

3,390

220 (485)

240 (530)

Double-wall 

1,000

791/860

1,000/1,020

2,350

220 (485)

240 (530)

Single-wall 

1,000

791

1,000/1,020

2,320

110 (243)

130 (287)

Double-wall  

500

791/860

500/520

1,315

120 (265)

150 (331)

Single-wall 

500

791

500/520

1,285

75 (166)

95 (210)

Double-wall, slimline

500

630/700

500/509

1,870

120 (265)

150 (331)

Single-wall, slimline

500

630

500/509

1,840

80 (177)

100 (221)

Double-wall

250

630/700

250/257

1,055

95 (210)

115 (254)

Single-wall

250

630

250/257

1,025

50 (111)

70 (155)

Summary of Contents for 9865302

Page 1: ...Serving Beer Tank OWNER S MANUAL Part No 9865302 Effective April 25 2018...

Page 2: ......

Page 3: ...Valve 7 Figure 5 Piercing Valve 7 3 5 Beer Distributor 8 Figure 6 Two Outlet Beer Distributor 8 3 6 Manway 8 3 7 Pressure Safety Valve 9 Figure 7 Pressure Safety Valve Components 9 3 8 Technical Spec...

Page 4: ...er Removal 17 Figure 15 Piercing Valve Removal 17 Figure 16 Inliner Removal 17 4 12 Pressurization 18 Figure 17 Adjusting Tank Pressure 18 4 13 Checking for Air Leaks in the Inliner 18 4 14 Cleaning t...

Page 5: ...vision 1 Please familiarize yourself with the information provided in this manual before you begin using your serving beer tank Please contact your Paul Mueller Company sales representative if you req...

Page 6: ...tly A signal word IMPORTANT will follow the symbol and will precede an explanatory statement 2 2 GENERAL SAFETY INFORMATION CAUTION Caution is required during the use inspection and maintenance of ser...

Page 7: ...The pressure vessel must be set up and installed in a horizontal position 6 Connections to the pressure vessel need to be attached strain free 7 Do not expose the pressure vessel to any vibrations dur...

Page 8: ...egarding safe operation of pressure vessels are to be observed TABLE 1 OPERATIONAL DATA Description Tank Cooling Contents See data plate See data plate Maximum admissible contents See data plate See d...

Page 9: ...Paul Mueller Company developed serving beer tanks in 1982 and has produced these convenient pressure vessels ever since Serving beer tank components are described as follows 1 Cooling 2 Inliner 3 Pie...

Page 10: ...ing spirals or cooling plates Double wall serving beer tanks require minimal modifications to surroundings but should be located in an area protected from frost and full sunlight See Figure 3 for cool...

Page 11: ...ves are used in conjunction with inliners see Section 3 4 Contact your Paul Mueller Company sales representative to purchase inliners See Section 6 for details FIGURE 4 INLINER INSIDE SERVING BEER TAN...

Page 12: ...ne serving beer tank and mount in on the other without spillage The check valve also prevents beer from flowing back into the tank from the hose maintaining beer quality in the tank The distributor ca...

Page 13: ...safety valve CAUTION If the pressure safety valve fails or is damaged it must be replaced immediately FIGURE 7 PRESSURE SAFETY VALVE COMPONENTS 3 8 TECHNICAL SPECIFICATIONS See Tables 2 3 and 4 for se...

Page 14: ...water temperature Approximately 2 5 C 36 5 F Cooling water delivery Approximately 250 liter hour Cooling time 10 C 5 C 50 F 41 F 20 hours Resistance cooling spiral 3 6 5 0 psi Dimensions manway 420mm...

Page 15: ...ANT Always inspect the serving beer tank for damage before transport Do not proceed with assembly of a damaged serving beer tank but return to Paul Mueller Company for inspection 4 2 STANDARD SERVING...

Page 16: ...ement of the serving beer tank in these instances CAUTION Various supplies are required for the beer tank a cool water source a compressor beer mains and beer hoses take up space around the serving be...

Page 17: ...nveyor band and the piercing valve Connect the tubes and place the second frame on the first frame At this point the second serving beer tank can be installed see Figure 9 The second tank must protrud...

Page 18: ...igure 10 FIGURE 10 SECURING THE PRESSURE SAFETY VALVE 4 8 CONNECTING THE WATER GLYCOL COOLING SYSTEM The serving beer tank s water cooling system consists of an entry and exit opening with a G 3 4 or...

Page 19: ...l 25 2018 Owner s Manual Part No 9865302 15 4 9 OPENING THE MANWAY 1 Release pressure from the serving beer tank through the pressure safety valve on the front 2 Open the tank by opening or removing t...

Page 20: ...from the plastic bubble wrap ensuring it does not come into contact with anything 4 With the plastic connection of the inliner facing the connection ferrule inside the serving beer tank push the inli...

Page 21: ...G VALVE 4 11 INLINER REMOVAL 1 Close the piercing valve by pulling the blue handle until it is pointing down 2 Remove the piercing valve with the spanner wrench see Figure 15 3 Remove the inliner and...

Page 22: ...INLINER 1 Open the valve on the piercing unit to allow any air in the inliner to escape 2 Close the valve on the piercing unit and wait for approximately 15 seconds before reopening the valve At this...

Page 23: ...containing chloride FIGURE 18 CLEANING THE SERVING BEER TANK 4 15 INLINER STORAGE Store inliners in a dry dark odor free cool area between 4 C 39 F and 20 C 68 F IMPORTANT Inliners should not be stor...

Page 24: ...nger at jsprenger paulmueller com 5 2 PARTS LIST Piercing valve Transit bush for piercing valve Pressure safety valve Sight glass DN50 Sight glass DN80 Manway Beer distributors Standard frames Inliner...

Page 25: ...er Tank Effective April 25 2018 Owner s Manual Part No 9865302 21 5 4 PIERCING VALVE Reference Number Part Number Description 1 9864959 Piercing valve 2 9864948 Gasket DN40 NBR 3 9864949 Gasket 50mm x...

Page 26: ...nk Effective April 25 2018 Owner s Manual Part No 9865302 22 5 5 TRANSIT BUSH FOR PIERCING VALVE Reference Number Part Number Description 1 9865249 Transit bush 2 9864951 Pin 3 9864950 Gasket 74mm x 6...

Page 27: ...r Part Number Description 1 9865070 Pressure safety valve complete assembly 2 9865071 Pressure gauge 3 9865069 Winged nut 4 9865068 Hose attachment 5 9865067 Sealing ring not shown 6 9865066 Holder li...

Page 28: ...5 8 SIGHT GLASS DN80 Reference Number Part Number Description 1 9865072 Swivel sight glass 2 9865073 Sight glass 3 9865074 O ring 4 9865075 Gasket Reference Number Part Number Description 1 9865076 Sw...

Page 29: ...ank Effective April 25 2018 Owner s Manual Part No 9865302 25 5 9 MANWAY Reference Number Part Number Description 1 9864953 Gasket 2 9865069 Spring 3 9865068 Hand wheel 4 9865262 Sealing ring 5 986526...

Page 30: ...64961 Beer distributor two lines 2 9864962 Beer distributor four lines 3 9864963 Beer distributor six lines 4 9865258 Non return valve 5 9865251 Clamping ring 6 9865252 Gasket 7 9865253 O ring 8 98652...

Page 31: ...5 11 STANDARD FRAMES Reference Number Part Number Description 1 9864973 Lateral girders and conveyor bands 500 liter 1 9864972 Lateral girders and conveyor bands 1 000 liter 1 9864965 Lateral girders...

Page 32: ...g nut is not tightened Adjust with spanner wrench Pressure safety valve Outlet valve is not closed Close outlet valve Sight glass is leaking Gasket is broken Replace gasket Pressure drops too fast Pre...

Page 33: ......

Page 34: ...jsprenger paulmueller com 1 800 MUELLER WWW PAULMUELLER COM 2018 Paul Mueller Company 16561 9865302...

Reviews: