5.2 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
☑
Engine is stopped and starting disabled.
☑
MTU Preservation and Represervation Specifications (A001070/..) are available.
Putting the engine into operation after extended out-of-service-periods (>3
months)
Item
Task
Engine
Depreserve (→ Preservation and Represervation Specifications A001070/..).
Valve drive
Lubricate valve gear every ≥ 6 months (→ Page 149).
Lube oil system
Check engine oil level (→ Page 189);
Preheat engine oil if required.
Fuel prefilter
Fuel prefilter, pressure
gauge
Align adjustable pointer with position of pressure indicator (→ Page 170).
HP fuel pump
Only for engines without oil priming pump:
Fill HP fuel pump with fresh engine oil (→ Page 155).
Raw water pump (if located
above waterline (only appli-
cable to engines with en-
gine-mounted heat exchang-
er or with optional remote
heat exchanger))
Prime with water (approx. 3 to 4 liters).
Coolant circuit
If engine is out of service for more than one year, change engine coolant
(→ Page 206).
Coolant circuit
Check coolant level (→ Page 205).
Coolant circuit
Preheat coolant with preheating unit.
Engine control system
Refer to automation system operating instructions.
ECU
Check plug connections (→ Page 236).
EMU
Check plug connections (→ Page 237)
EIM
Check plug connections (→ Page 238).
80 | Operation | MS15034/00E 2018-08
TIM-ID: 0000010092 - 006