476 – AL Crash Rec. Init. Error
ZKP-Number: 1.8010.007
Cause
Corrective action
Crash recorder initialization error.
1. Check setting with DiaSys.
2. Contact Service.
482 – SD T-Exhaust C
ZKP-Number: 1.8004.596
Cause
Corrective action
Exhaust temperature sensor on A-
side faulty; Short circuit or wire
break
u
Check sensor and cabling (B4.23), replace as necessary.
483 – SD T-Exhaust D
ZKP-Number: 1.8004.597
Cause
Corrective action
Exhaust temperature sensor on A-
side faulty; Short circuit or wire
break
u
Check sensor and cabling (B4.24), replace as necessary.
492 – AL ETC4 CutIn Failure
ZKP-Number: 1.8004.202
Cause
Corrective action
ETC4 could not be cut in.
u
Check control valve on ETC 4.
493 – AL ETC3 CutIn Failure
ZKP-Number: 1.8004.203
Cause
Corrective action
ETC3 could not be cut in.
u
Check control valve on ETC 3.
500 – AL Wiring POM Starter 1
ZKP-Number: 1.4500.900
Cause
Corrective action
A wiring fault was detected in the
connection between starter 1 and
POM. This may be a missing
consumer, a wire break, or a short
circuit.
u
Check connection between POM and starter.
126 | Troubleshooting | MS15034/00E 2018-08
TIM-ID: 0000018389 - 004
Summary of Contents for 8V4000M*3 series
Page 1: ...Operating Instructions Diesel engine 8V4000Mx3x MS15034 00E...
Page 3: ......
Page 4: ......