207 – SD T-Exhaust B
Yellow alarm.
Associated parameter 1.8004.577
Cause
Corrective action
Exhaust temperature sensor on
B side defective, short circuit or
wire break.
u
Check sensor and cabling (B4.22), replace if necessary. Fault is
rectified following engine restart.
211 – SD P-Lube Oil
Red alarm. Engine shutdown.
Associated parameter 1.8004.563
Cause
Corrective action
Engine oil pressure sensor after
filter defective, short circuit or
wire break.
u
Check sensor and cabling (B5.1), replace as necessary. Fault is
rectified following engine restart.
212 – SD P-Coolant
Red alarm.
Associated parameter 1.8004.564
Cause
Corrective action
Coolant pressure sensor after
engine defective, short circuit or
wire break.
u
Check sensor and cabling (B16.1), replace if necessary. Fault is
rectified following engine restart.
214 – SD P-Crankcase
Red alarm.
Associated parameter 1.8004.568
Cause
Corrective action
Crankcase pressure sensor
defective, short circuit or wire
break.
u
Check sensor and cabling (B50), replace as necessary. Fault is
rectified following engine restart.
216 – SD T-Lube Oil
Red alarm. Engine shutdown.
Associated parameter 1.8004.575
Cause
Corrective action
Engine oil temperature sensor
after oil heat exchanger
defective, short circuit or wire
break.
u
Check sensor and cabling (B7), replace as necessary. Fault is
rectified following engine restart.
100 | Troubleshooting | MS150097/01E 2013-10